Page 1: ... Instructions BeforeFirstUse of ThisProduct SaveThisManual For FutureReference I RRFTSMRN BATTERY OPERATED BACKUP SUMP PUMP Safety Instructions Operation Installation Troubleshooting Repair Parts Sears Roebuck and Co Hoffman Estates IL 60179 U S A PRINTED IN U S A Form No F642 9510 Rev 11 4 98 ...

Page 2: ...d or flooded 7 Do not modify cord or plug 8 Do not attempt to service charger it has no user ser viceable parts If charger is dropped struck or otherwise damaged take it to a qualified service technician SAVE THESE INSTRUCTIONS RULES FOR SAFE INSTALLATION AND OPERATION Carefully read and follow all safety instructions in this n_ariual or on pump _k This is the safety alert symbol When you see this...

Page 3: ...al switch actuated op eration alarm is locked out until about 4 sec6nds after float switch has dropped to OFF position cycle can then begin again Test alarm by pushing ALARM TEST RESET button when alarm is not sounding Alarm will then sound as long as but ton is held down Pushing ALARM TEST RESET button to test alarm overrides lockout so alarm can be tested at any time If alarm sounds check operat...

Page 4: ...nough for proper operation To lower high water level adjust switch on primary sump pump See primary pump owner s manual 3 Drain sump Measure down 11 inches from top of sump mark this point on side of sump Install tee with center of threaded inlet at least this far below top of sump to allow sufficient room for float switch to swing see Figure 2A 4 Make sure that installation will not interfere wit...

Page 5: ... battery Press ALARM TEST RESET button on charger If alarm continues to sound disconnect one charger lead from the battery and reconnect it Press ALARM TEST RESET again alarm will stop sounding 1 Connect charger as shown in Figure 3 A Connect Positive lead from charger to positive battery post B Connect Negative lead from charger to negative bat tery post C Third lead from charger is factory conne...

Page 6: ...lve is installed and functioning be tween primary pump discharge and Backup Sump Pump tee Figure 6 2 Check for obstruction in discharge pipe 3 Discharge pipe length and or height exceeds capacity of pump See Table I Page 4 for pump capacity 4 Check for low or defective battery Figure 7 Pump cycles too frequently 1 Tether length too short on automatic float switch Make sure that tether is at least ...

Page 7: ...rt Description 1 2 3 4 5 6A 6B 7 8 9 10 11 12 PS217 5E PS17 41 CC0030 13 U17 1148 U17 1149 PS17 100 PS 117 77A PS22 1 PS78 3P U78 846P U78 876P Switch Assembly Pump Complete Cord Clamp Fuse Holder 15 Amp Time Delay Fuse 2 suppliedt Wire Ten ninal 4 Red Battery Terminal Clamps 2 Req Battery Case includes strap and strap brackets Charger Check Valve Hose Clamp 1 min 2 max S S Pips Adapter Tee 1 1 2 ...

Page 8: ...orthe repairor replacementpartsyouneed Cull7 am 7 pm 7 daysaweek 1 800 366 PART 1 800 386 7278 ForIn homemajorbrandrepairservice Call24 hoursaday 7 daysaweek 1 800 4 REPAIR 1 800 473 7247 Forthe locationof a SearsRepairServiceCenterinyourarea Call 24 hoursa day 7 daysaweek 1 800 488 1222 Forinformation onpurchasing a Sears MaintenanceAgreement orto inquire aboutan existingAgreement callg am 5 pro ...