background image

5. Fan Assembly. (cont.)

page 5

With the hanging bracket secured to the outlet box and 
able to support the fan, you are now ready to hang your 
fan. Grab the fan firmly with two hands. Slide downrod 
through opening in hanging bracket and let hanging ball 
rest on the hanging bracket. Turn the hanging ball slot 
until it lines up with the hanging bracket tab.

WARNING

: Failure to align slot in hanging ball with tab in 

hanging bracket may result in serious injury or death.

Tip:

 Seek the help of another person to hold the 

stepladder in place and to help lift the fan up to you once 
you are set on the ladder. 

Find a secure attachment point (wood ceiling joist highly 
recommended) and secure safety cable. It will be necessary 
to use a heavy duty wood screw, washer and lock washer 
(not supplied) with the safety cable loop. If necessary, 
adjust the loop at the end of the safety cable. The loop at 
the end of the safety cable should just fit over the threads 
on the wood screw. Test safety cable by pulling on loose 
end with pliers. If safety cable slips, the loop must be 
adjusted tighter. Extra cable slack can be left in ceiling 
area. 

6. Wiring.

WARNING

: Turn off circuit breakers to current fixture 

from breaker panel and be sure switch is turned to the 
OFF position.

CAUTION

Be sure outlet box is properly grounded and 

that a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code. If 
you are unfamiliar with electrical wiring or if the 
house/building wires are different colors than those 
referred to below, please use a qualified electrician.

Note: 

Excess lead wire length from the fan can be cut to 

the desired length and then stripped.

When downrod is secured in place on the hanging 
bracket, electrical wiring can be made as follows:
Connect 

BLACK

 wire from fan to 

BLACK

 wire from 

ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from 

ceiling with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from fan 

to 

BARE

/

GREEN

 wire from ceiling with wire connector 

provided.  

Since this fan is not light kit adaptable,  you will need to 
cap off the 

BLUE

 wire with a wire connector (as shown 

with arrow in diagram).

* Wrap each wire connector separately with electrical 
tape as an extra safety measure.

wire

connector

black

black

white

white

blue

black supply wire

ground

 (green

or bare)

white supply wire

from ceiling

from fan

ground 
(green or bare)

*

hanging ball slot

hanging bracket tab

motor housing

safety cable

safety cable loop

wood

ceiling

joist

wood screw

and washer

[”

Wiring

” 

continued on next page.

]

Summary of Contents for Velocity VE58

Page 1: ...et Installation pg 3 Fan Assembly pgs 4 5 Wiring pgs 5 6 Canopy Assembly pg 6 Blade Assembly pg 7 Wall Control Operation pg 8 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty...

Page 2: ...house wire and two lead wires from the fan If your house wire is larger than 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for th...

Page 3: ...pairs Check against parts inventory that all parts have been included page 2 IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety a canopy 1 piece b hang...

Page 4: ...outlet box If installing on a vaulted ceiling face opening of hanging bracket towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the hanging...

Page 5: ...n hardware pack Slide yoke cover canopy cover and canopy over downrod Refer to diagram 3 Note Canopy cover must be turned with shiny side toward the motor housing Thread safety cable and wires through...

Page 6: ...be sure switch is turned to the OFF position CAUTION Be sure outlet box is properly grounded and that a ground wire GREEN or Bare is present Make sure all electrical connections comply with Local Code...

Page 7: ...interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following mea...

Page 8: ...ts in blade plate with holes in blade as shown and lower blade arm over blade holes Insert 3 blade attachment screws along with washers with fingers first and then tighten screws securely with a Phill...

Page 9: ...s If fan does not function please refer to Troubleshooting section to solve any issues before contacting Customer Service A ceiling fan will allow you to raise your thermostat setting in summer and lo...

Page 10: ...purchaser any fan motor that fails to operate satisfactorily when failure results from normal use RETURN FAN MOTOR ONLY shipping prepaid to Craftmade Industries We will repair or ship purchaser a rep...

Page 11: ...ci n el ctrica P gs 5 6 Colocaci n de la cubierta decorativa P g 6 Colocaci n de las aspas P g 7 Funcionamiento del control de pared P g 8 Verificaci n del funcionamiento del ventilador P g 8 Localiza...

Page 12: ...dos para aceptar s lo un cable de calibre 12 de la casa y dos cables principales del ventilador Si el calibre del cable de la casa es superior al 12 o hay m s de un cable de la casa para conectar a lo...

Page 13: ...verificar que se incluyeron todas p gina 2 RECORDATORIO IMPORTANTE Se tienen que utilizar las piezas provistas con este ventilador para una instalaci n adecuada y su seguridad a cubierta decorativa 1...

Page 14: ...techo abovedado colocar el soporte de montaje con la abertura dirigida hacia la parte alta del techo Arreglar el alambrado el ctrico los cables en la parte de atr s del soporte y lejos de la abertura...

Page 15: ...por el tubo Referirse al diagrama 3 Nota se debe voltear la tapa de la cubierta decorativa para que el lado brillante d al bastidor del motor Pasar el cable de seguridad y los cables por la bola que s...

Page 16: ...le bastidor del motor viga de madera parte saliente del soporte de montaje ranura en la bola que sirve para colgar cable de seguridad bucle del cable de seguridad tornillo para madera y arandela Ya qu...

Page 17: ...a y puede radiar energ a de radiofrecuencia y si no se instala y no se usa seg n las instrucciones puede causar interferencia adversa en la radiocomunicaci n Sin embargo no hay ninguna garant a de que...

Page 18: ...para el aspa encima del aspa Introducir 3 tornillos para fijar las aspas junto con las arandelas con los dedos primero y luego apretar los tornillos bien con un destornillador de estrella Phillips Re...

Page 19: ...l cortacircuitos Poner a prueba las velocidades del ventilador con el control de pared Empezar en estado de APAGADO 0 sin movimiento de las aspas y experimentar con la 4 diferentes velocidades del ven...

Page 20: ...ntilador y pagaremos los gastos de env o de regreso GARANT A DE 5 A OS CRAFTMADE reemplazar o reparar sin costo al comprador original cualquier motor de ventilador que no funcione de manera satisfacto...

Reviews: