3. Installation Preparation.

ON

OFF

ON

OFF

4. Hanging Bracket Installation.

Turn off circuit breakers to current fixture from breaker 
panel and be sure operating light switch is turned to the 
OFF position. 

WARNING: 

Failure to disconnect power supply prior to 

installation may result in serious injury.

Remove existing fixture. 

WARNING:

 When using an existing outlet box, be sure the 

outlet box is securely attached to the building structure and 
can support the full weight of the fan. Ensure outlet box is 
clearly marked "Suitable for Fan Support." If not, it must be 
replaced with an approved outlet box. Failure to do so can 
result in serious injury.

CAUTION

: Be sure outlet box is properly grounded and that a 

ground wire (

GREEN

 or bare) is present.

Install hanging bracket to outlet box using original screws, 
spring washers and flat washers provided with new or 
original outlet box.

If installing on a vaulted ceiling, face 

opening of hanging bracket towards high point of ceiling. 
Arrange electrical wiring around the back of the hanging 
bracket and away from the bracket opening.

*Note

: It is very important that you use the proper hardware 

when installing the hanging bracket as this will support the 
fan. 

Installation requires these tools:

Phillips screwdriver, flathead screwdriver, adjustable 
pliers or wrench, stepladder, wire cutters, and rated 
electrical tape.

downrod

installation

flushmount

installation

To prevent personal injury and damage, ensure that 
the hanging location allows the blades a clearance 
of 7 feet (2.13m) from the floor and 30in. (76cm) 
from any wall or obstruction. 
The 48in fan is suitable for room sizes up to 225 
square feet (20.9 square meters).
The 52in fan is suitable for room sizes up to 400 
square feet (37.2 square meters).

7 feet

(2.13 m) (76 cm)

30 

inches

blade edge

12f

t.

 - 20f

t.

12ft. - 20ft.

(3.66m - 6.1m)

(3.66m - 6.1m)

Vaulted ceiling 
angle is not to 
exceed 20 degrees.  

12f

t.

 - 15f

t.

12ft. - 15ft.

(3.66m - 4.57m)

(3.66m - 4.57m)

48in fan

52in fan

This fan can be mounted with a 

downrod

on a regular (no-slope) or vaulted ceiling. The 
hanging length can be extended by purchasing 
a longer downrod (0.5in./1.27cm diameter). 
Other installation, such as 

flushmount

, is 

not

 

available for this fan.

hanging bracket

spring washers

outlet box screws

flat washers

Summary of Contents for Targas TG48

Page 1: ... TG52 Targas Table of Contents Safety Tips pg 2 Unpacking Your Fan pg 3 Parts Inventory pg 3 Installation Preparation pg 4 Hanging Bracket Installation pg 4 Fan Assembly pgs 5 7 Wiring pg 8 Wiring Wall Control pg 8 Canopy Assembly pg 9 Shade Installation pg 9 Wall Control Operation pg 9 Testing Your Fan pg 10 Troubleshooting pg 11 Parts Replacement pg 11 Warranty pg 11 ...

Page 2: ...ntrol device or control fan speed with a full range dimmer switch Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan 8 Do not operate the reverse switch until the fan has come to a complete stop Note If using remote control with reverse capability reverse fan blade direction only when on LOW speed 9 Do not insert anything between the fan blades while the...

Page 3: ...ts have been included 2 Parts Inventory a canopy 1 piece b hanging bracket 1 piece c downrod and hanging ball with pin and clip 1 piece d yoke cover 1 piece e canopy cover in hardware pack 1 piece f motor housing 1 piece g LED light kit preassembled to motor 1 piece h shade 1 piece i wall control and plate 2 pieces j blade 3 pieces k blade plate 3 pieces l hardware packs IMPORTANT REMINDER You mus...

Page 4: ...k of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support the fan Installation requires these tools Phillips screwdriver flathead screwdriver adjustable pliers or wrench stepladder wire cutters and rated electrical tape downrod installation flushmount installation To prevent persona...

Page 5: ... Locate 9 blade attachment screws washers in hardware pack Slide blade through one of the narrow rectangular openings on center band aligning holes in blade with holes in blade arm located inside motor housing Insert 3 blade attachment screws washers with fingers first and then tighten screws securely with a Phillips screwdriver Repeat procedure for each remaining blade Re attach top plate and yok...

Page 6: ...ver in hardware pack Slide yoke cover canopy cover and canopy over downrod Refer to diagram 3 Note Canopy cover must be turned with shiny side toward the motor housing Thread safety cable and wires through hanging ball then slide hanging ball over downrod the top of the downrod should be noted as having a set screw hole use this hole when setting the set screw Insert stop pin into top of downrod a...

Page 7: ...der in place and to lift the fan up to you once you are set on the ladder Find a secure attachment point wood ceiling joist highly recommended and secure safety cable It will be necessary to use a heavy duty wood screw washer and lock washer not supplied with the safety cable loop If necessary adjust the loop at the end of the safety cable The loop at the end of the safety cable should just fit ov...

Page 8: ...n off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position CAUTION Be sure outlet box is properly grounded and that a ground wire GREEN or Bare is present Make sure all electrical connections comply with Local Codes or Ordinances and the National Electrical Code If you are unfamiliar with electrical wiring or if the house building ...

Page 9: ...FF Move slide knob up or down for LIGHT brightness Locate 2 screws on underside of hanging bracket and remove screw closest to the open end of the hanging bracket Partially loosen the other screw Lift canopy to hanging bracket Place rounded part of slotted hole in canopy over loosened screw in hanging bracket and push up Twist canopy to lock Re insert screw that was removed and then tighten both s...

Page 10: ...ompletely off before moving the reverse switch Set reverse switch to recirculate air depending on the season LEFT position in summer diagram 1 RIGHT position in winter diagram 2 A ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort Important Reverse switch must be set either completely LEFT o...

Page 11: ...urn fan shipping prepaid to Craftmade We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY CRAFTMADE will repair or replace at no charge to the original purchaser any fan motor that fails to operate satisfactorily when failure results from normal use RETURN FAN MOTOR ONLY shipping prepaid to Craftmade Industries We will repair or ship purchaser a re...