2. Parts Inventory.

a

. hanging bracket. 1 piece

 

b

. canopy. 1 piece

 

c

. downrod and hanging ball. 1 piece

 

d

. motor housing. 1 piece

 

e

. yoke cover. 1 piece

 

f

. blade arm. 5 pieces 

 

g. 

wall control. 2 pieces

h.

 plate. 1 piece

 

i.

 remote control cover. 1 piece

   

j.

 faceplate. 3 pieces

 

k

. LED light kit.1 piece

 

l

. canopy cover (in hardware pack). 1 piece

 

m

. blade*. 5 pieces

 

n

. fitter plate. 1 piece

 

o

. glass shade. 1 piece

p

.

 

metal cover. 1 piece

   

q

. metal cover plate. 1 piece

r

. hardware packs 

d

g

n

e

f

a

b

c

page 2

1. Unpacking Your Fan.

o

p

l

         

   

IMPORTANT REMINDER

: You must 

use the parts provided with this fan for
proper installation and safety.

k

m

h

j

i

*

Blade drawings in this manual

 are representative only

1

1

-

2

2

-

DIM  ON

q

Carefully open the packaging. Remove items from 
Styrofoam inserts. Remove motor housing and 
place on carpet or Styrofoam to avoid damage to 
finish. *The motor stabilization pieces may be 
dicarded at this time. Do not discard fan carton or 
Styrofoam inserts should this fan need to be 
returned for repairs.
Check against parts inventory that all parts have 
been included.

r

w/ wall control

Summary of Contents for STY52CH

Page 1: ...Installation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pgs 5 6 Canopy Assembly pg 6 Blade Assembly pg 7 Light Kit Assembly Optional pgs 7 8 Handheld Remote Contro...

Page 2: ...than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are no...

Page 3: ...r hardware packs d g n e f a b c page 2 1 Unpacking Your Fan o p l IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety k m h j i Blade drawings in this...

Page 4: ...cal wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support...

Page 5: ...to diagram 2 Thread downrod into the motor housing yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously...

Page 6: ...te white black supply wire ground green or bare white supply wire from ceiling from fan ground green or bare wiring for fan With the hanging bracket secured to the outlet box and able to support the f...

Page 7: ...ncouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the...

Page 8: ...es with motor screw holes and attach blade arm with blade arm screws lock washers Before securing screws permanently repeat procedure with remaining blade arms Secure all screws Note Tighten blade arm...

Page 9: ...in fitter plate Twist the LED light kit to lock Re insert screw that was previously removed and securely tighten all 3 screws Align grooves on glass shade with nodules inside of LED light kit and push...

Page 10: ...a click at each end indicating that the remote control cover has closed completely IMPORTANT Store the remote control away from excess heat or humidity To prevent damage to remote control remove the...

Page 11: ...ower from circuit box Test wall control optional installation by locating ON OFF slider switch on wall control then set to the ON position Test fan speeds Next locate handheld remote control Test fan...

Page 12: ...om improper installation or use of this product In no case shall the company be liable for any consequential damages for breach of this or any other warranty expressed or implied whatsoever This limit...

Page 13: ...porte de montaje P g 3 Ensamblaje del ventilador P gs 4 5 Instalaci n el ctrica P gs 5 6 Colocaci n de la cubierta decorativa P g 6 Colocaci n de las aspas P g 7 Instalaci n del juego de luz Opcional...

Page 14: ...l 12 o hay m s de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informarse sobre el tama o correcto de conec...

Page 15: ...rreter a 1 unidad m aspa 5 unidades n placa de conexi n 1 unidad o pantalla de vidrio 1 unidad p cubierta de metal 1 unidad q placa de la cubierta de metal 1 unidad r paquetes de art culos de ferreter...

Page 16: ...e suplen corriente a la caja de salida y asegurarse de que el interruptor de luz est APAGADO ADVERTENCIA El no desconectar el suministro de fuerza antes de la instalaci n puede tener por resultado les...

Page 17: ...los cables Volver a introducir el perno y la clavija que se quitaron anteriormente Apretar los tornillos de fijaci n del cuello y la tuerca completamente Referirse al diagrama 2 Localizar la tapa de l...

Page 18: ...aci n el ctrica ADVERTENCIA Apagar los cortacircuitos en el panel de electricidad que suplen corriente a la caja de salida y asegurarse de que el interruptor de luz est APAGADO PRECAUCION Asegurarse d...

Page 19: ...ue se puede determinar apagando y prendiendo el equipo se le urge al usuario a intentar rectificar la interferencia tomando una o m s de las medidas que siguen Orientar la antena de nuevo o localizarl...

Page 20: ...desechar los soportes de pl stico guardar los tornillos arandelas de seguridad para asegurar los brazos para el aspa Alinear los agujeros de uno de los brazos para las aspas con los agujeros para los...

Page 21: ...LED y empujar la pantalla de vidrio delicadamente hacia arriba Girar la pantalla de vidrio hacia la DERECHA en sentido de las agujas del reloj hasta que se quede encajada Con MUCHO CUIDADO jalar haci...

Page 22: ...os extremos m s angostos de la cubierta del control remoto antes de cerrarla Apretar la parte superior e inferior de la cubierta del control remoto hasta que se oiga un clic en cada extremo lo cual in...

Page 23: ...de pared instalaci n opcional localizando el interruptor corredero de APAGADO y ENCENDIDO en el control de pared luego ponerlo en posici n de ENCENDIDO ON Poner a prueba las velocidades del ventilado...

Page 24: ...bola que sirve para colgar Localizaci n de fallas ADVERTENCIA El no desconectar el suministro de fuerza el ctrica antes de hacer localizaci n de fallas para cualquier problema de instalaci n el ctric...

Reviews: