background image

page 6

8. Blade Assembly.

9. Light Kit Assembly. 

Remove 1 screw from motor plate on 
underside of motor housing and partially 
loosen the other 2 screws. 

Connect the 

WHITE

 wire from the light kit fitter 

to the 

WHITE

 wire from motor housing. 

Connect the 

BLACK

 wire from the light kit fitter 

to the 

BLACK 

wire from the motor housing. 

Make sure the molex connections snap 
together securely.

Carefully arrange wiring and  align slotted 
holes in  light kit fitter with loosened screws in 
motor plate. Twist to lock. Re-insert screw that 
was previously removed and securely tighten 
all 3 screws with Phillips screwdriver.

Remove socket ring from light kit fitter.  
Carefully raise large and small glass shades to 
motor housing, allowing socket to come 
through holes. Replace socket ring on socket to 
secure shades.

Install one medium base 13 watt max. compact 
fluorescent bulb (included).

Important

: When replacing bulb, please allow 

bulb and shades to cool down before touching 
them.

Locate 6 blade attachment screws and 12 
decorative screws, hex nuts and washers in the 
hardware packs. Align holes in blade with holes in 
blade arm. (

Note label on blade indicating 

THIS SIDE UP.

) Push decorative screws through 

from underside and insert hex nuts (along with 
washers and spring washers) from topside. 
Tighten all 4 screws securely. Repeat procedure 
with remaining blades.

Slide blade arm through two of the narrow, 
rectangular openings on motor housing, aligning 
holes in blade arm with holes in cushion inside of 
motor housing--

refer to drawing at right

Attach blade arms with screws. Tighten screws 
securely.  Repeat procedure with remaining blade 
arms.

Note:

 Tighten blade arm screws twice a year.

blade

hex nut

washers

blade arm

motor
housing

decorative

screws

screws

WHITE

BLACK

WHITE

BLACK

molex
connections

motor plate

light kit fitter

socket ring

small glass 
shade

large glass 
shade

bulb

spring

washers

Summary of Contents for STU54PLN3

Page 1: ...g 5 Attachment of Motor Housing pg 5 Blade Assembly pg 6 Light Kit Assembly pg 6 Automated Learning Process Activating Code pg 7 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty pg 9 net weight of fan 15 44 lb 7 0 kg PRINTED IN CHINA READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE E206035 F P O F P O For Placement Only For Placement Only For Model STU54PLN3 ...

Page 2: ...ore than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CETL Canada or ETL USA listed and marked suitable for use with the model fan you are installing Switches must be CETL Canada or ETL USA general use switches Refer to ...

Page 3: ...his fan for proper installation and safety 2 Parts Inventory a mounting plate 1 piece b motor housing 1 piece c light kit fitter 1 piece d socket ring pre attached to light kit fitter 1 piece e blade 3 pieces f blade arm 3 pieces g safety cable already attached to motor 2 pieces h small glass shade 1 piece i large glass shade 1 piece j remote control transmitter wall control 2 pieces k case for re...

Page 4: ...n using an existing outlet box be sure the outlet box is securely attached to the building structure and can support the full weight of the fan Ensure the outlet box is clearly marked Suitable for Fan Support If not it must be replaced with an approved outlet box Failure to do so can result in serious injury CAUTION Be sure outlet box is grounded properly and that a ground wire GREEN or bare is pr...

Page 5: ... and pulling on the cable Adjust slack in cable to a hands length and secure vice by tightening screw and nut securely Refer to diagram 2 The loop at the end of the safety cable should just fit over the threads on the wood screw Test safety cable by pulling on loose end with pliers If the safety cable slips the screw and nut on the vice must be set tighter Remove large screw beside the red dot in ...

Page 6: ... with wire connector provided Connect all GROUND GREEN wires together from fan to BARE GREEN wire from ceiling with wire connector provided If you intend to control the fan light with a separate light switch connect BLUE wire from fan to the BLACK or RED supply from the independent switch Wrap each wire connector separately with electrical tape as an extra safety measure 7 Attachment of Motor Hous...

Page 7: ...pact fluorescent bulb included Important When replacing bulb please allow bulb and shades to cool down before touching them Locate 6 blade attachment screws and 12 decorative screws hex nuts and washers in the hardware packs Align holes in blade with holes in blade arm Note label on blade indicating THIS SIDE UP Push decorative screws through from underside and insert hex nuts along with washers a...

Page 8: ...fan power on press and hold LEARN button on front of remote control and on wall control if applicable for 5 seconds within 60 seconds of powering fan in order to synchronize with fan motor UP LIGHT Use for up light if applicable DOWN LIGHT Use for down light ON OFF Use to turn transmitter on or off Replace the battery cover on transmitter remote control FRONT 1 2 3 4 D 12V ON ECE ON UP BULB DOWN B...

Page 9: ...rvice Fan must be on LOW before setting the fan in reverse Use button to recirculate air depending on the season A ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort NOTE If the wall remote control interferes with other appliances change code switches on the wall remote control to another co...

Page 10: ...mpted under this warranty Neither Craftmade Ellington nor the manufacturer will assume any liability resulting from improper installation or use of this product In no case shall the company be liable for any consequential damages for breach of this or any other warranty expressed or implied whatsoever This limitation as to consequential damages shall not apply in states where prohibited Problem Fa...

Page 11: ... motor Pág 5 Colocación de las aspas Pág 6 Instalación del juego de luz Pág 6 Proceso de aprendizaje automático El activar el código Pág 7 Verificación del funcionamiento del ventilador Pág 8 Localización de fallas Pág 9 Piezas de repuesto Pág 9 Garantía Pág 9 IMPRESO EN CHINA LEER ESTAS INSTRUCCIONES Y GUARDARLAS PARA UTILIZACION FUTURA peso neto del ventilador 7 0 kg 15 44 lb Guía de instalación...

Page 12: ...o hay más de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informarse sobre el tamaño correcto de conectores para cable que se debe usar 5 Los diagramas eléctricos son únicamente para referencia Los juegos de luz que no se incluyen con el ventilador deben tener el símbolo CETL Canadá o ETL EEUU y también de...

Page 13: ...ra una instalación adecuada y su seguridad a placa de montaje 1 unidad b bastidor del motor 1 unidad c conectador para el juego de luz 1 unidad d anillo del portalámpara fijado de antemano al conectador para el juego de luz 1 unidad e aspa 3 unidades f brazo para el aspa 3 unidades g cable de seguridad fijado de antemano al motor 2 unidades h pantalla de vidrio pequeña 1 unidad i pantalla de vidri...

Page 14: ...salida y asegurarse de que el interruptor de luz esté APAGADO ADVERTENCIA El no desconectar el suministro de fuerza antes de la instalación puede tener por resultado lesiones graves Quitar el aparato existente ADVERTENCIA Si utiliza una caja de salida eléctrica existente asegurarse de que la caja de salida esté firmemente conectada a la estructura del edificio y que sea capaz de sostener el peso t...

Page 15: ...apretando bien el tornillo y la tuerca Referirse al diagrama 2 El bucle en el extremo del cable de seguridad debe ser de tal tamaño que pase justo sobre la punta de la parte roscada del tornillo para madera Poner el cable a prueba jalando la parte suelta en la punta del cable con alicate Si el cable se desliza o se reduce el bucle del cable por donde pasa el tornillo hay que apretar el tornillo y ...

Page 16: ...able provisto Conectar todos los conductores a TIERRA VERDES del ventilador al cable PELADO VERDE del techo con un conector para cable provisto Si usted piensa controlar la luz del ventilador con un interruptor distinto conectar el cable AZUL del ventilador al conductor NEGRO o ROJO que corresponde al interruptor independiente Como una medida de seguridad adicional envolver cada conector para cabl...

Page 17: ...en las pantallas y la bombilla antes de tocarlas 8 Colocación de las aspas Localizar 6 tornillos para sujetar las aspas y 12 tornillos decorativos tuercas hexagonales y arandelas en los paquetes de artículos de ferretería Alinear los agujeros en una de las aspas con los agujeros en un brazo para el aspa Tener en cuenta la etiqueta en el aspa que indica ESTE LADO HACIA ARRIBA Introducir los tornill...

Page 18: ...electricidad oprimir y mantener sujeto el botón LEARN que se encuentra en la parte delantera del control remoto y en el control de pared si aplica por 5 segundos dentro de 60 segundos de haber conectado la electricidad que va al ventilador para sincronizarlo con el motor del ventilador LUCES SUPERIORES Se usa para las luces superiores si aplica LUCES INFERIORES Se usa para las luces inferiores APA...

Page 19: ... asunto antes de comunicarse con el Servicio al cliente Hay que poner el ventilador en posición BAJA antes de poner el ventilador en reversa Usar el botón para que circule bien el aire dependiendo de las estaciones del año Un ventilador de techo le permitirá subir el termostato en verano y bajarlo en invierno sin notar una diferencia en su comodidad NOTA Si el control de pared control remoto inter...

Page 20: ...pecíficamente el deterioro en el acabado u otras partes debido al tiempo o exposición al aire marino bajo esta garantía Ni Craftmade Ellington ni el fabricante se harán responsables por lo que pasa por una instalación inadecuada o el uso impropio de este producto La compañía no se hará responsable en ningún caso de ningún daño emergente por incumplimiento de esta o cualquier otra garantía expresad...

Reviews: