4. Hanging Bracket Installation.

page 3

ON

OFF

ON

OFF

3. Installation Preparation.

To prevent personal injury and damage, ensure 
that the hanging location allows the blades a 
clearance of 7 ft. (2.13m) from the floor and 30in. 
(76cm) from any wall or obstruction. 
This fan is suitable for room sizes up to 400 square 
feet (37.2 square meters).

This fan can be mounted with a 

downrod

on a regular (no-slope) or vaulted ceiling.  The 
hanging length can be extended by purchasing 
a longer downrod (0.5 in /1.27 cm diameter). 
Other installation, such as

 flushmount

, is 

not

 

available for this fan.

Installation requires these tools:

Phillips screwdriver, flat-head screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape.

Vaulted ceiling 
angle is not to 
exceed 20 degrees.

downrod

installation

flushmount

installation

12f

t.

  - 20f

t.

12ft. - 20ft.

(3.66m - 6.1m)

(3.66m - 6.1m)

blade edge

7 feet

(2.13m)

(76cm)

30 

inches

Turn off circuit breakers to current fixture from breaker 
panel and be sure operating light switch is turned to the
OFF position. 

WARNING

Failure to disconnect power supply prior to 

installation may result in serious injury.

Remove existing fixture. 

WARNING

When using an existing outlet box, be sure the 

outlet box is securely attached to the building structure and 
can support the full weight of the fan. Ensure the outlet box 
is clearly marked "Suitable for Fan Support." If not, it must 
be replaced with an approved outlet box. Failure to do so 
can result in serious injury.

CAUTION

Be sure outlet box is grounded properly and that 

a ground wire (

GREEN 

or bare) is present.

Install hanging bracket to outlet box using original 
screws, spring washers and flat washers provided with 
new or original outlet box.* If installing on a vaulted 
ceiling, face opening of hanging bracket towards high 
point of ceiling. Arrange electrical wiring around the 
back of the hanging bracket and away from the bracket 
opening.

*Note

: It is very important that you use the proper 

hardware when installing the hanging bracket as this will 
support the fan. 

hanging bracket

spring washers

outlet box screws

flat washers

Summary of Contents for Stonegate STO52

Page 1: ...Fan pg 2 Parts Inventory pg 2 Installation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 5 Canopy Assembly pg 6 Blade Assembly pg 6 Light Kit Assembly pg 7 Testing...

Page 2: ...ng fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be ETL or UL listed an...

Page 3: ...hardware packs a b c d f h k g 1 Unpacking Your Fan Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish Do...

Page 4: ...ture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing f...

Page 5: ...yoke set screws and nut securely Refer to diagram 2 Slide yoke cover and canopy over downrod Refer to diagram 3 Thread wires through hanging ball then slide hanging ball over downrod the top of the do...

Page 6: ...CAUTION Be sure outlet box is properly grounded and that a ground wire GREEN or Bare is present Make sure all electrical connections comply with Local Codes or Ordinances and the National Electrical C...

Page 7: ...label on blade indicating THIS SIDE UP and turn blade so that label faces up Insert 3 decoratvie nuts from UNDERSIDE of blade i e the side that will face the floor making sure to completely insert ea...

Page 8: ...labeled LIGHT It is recommended that you test fan before finalizing installation Restore power from circuit box and light switch if applicable Test fan speeds with the pull chain labeled FAN Start at...

Page 9: ...repair any fan which has faulty performance due to a defect in material or workmanship Contact Craftmade Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to...

Reviews: