background image

WARNING

: Turn off circuit breakers to current fixture 

from breaker panel and be sure switch is turned to the 
OFF position.

 
CAUTION

Be sure outlet box is properly grounded and 

that a ground wire (

GREEN

 or Bare) is present.

 

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code. If you 
are unfamiliar with electrical wiring or if the house/building 
wires are different colors than those referred to in the 
instructions below, please use a qualified electrician.

 
Note

Excess lead wire length from the fan can be cut 

to the desired length and then stripped.

 

When downrod is secured in place on the hanging 
bracket, electrical wiring can be made as follows:
Connect 

BLACK

 wire from fan to 

BLACK

 wire from 

ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from 

ceiling with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from fan 

to 

BARE

/

GREEN

 wire from ceiling with wire connector 

provided.

 

Since this fan does not come with a light kit, you will 
need to cap off the 

BLUE 

wire with a wire connector 

(as shown with arrow in diagram). 
[

Note

: If you elect to purchase a light kit for the fan, 

the 

BLUE

 wire from the fan must be connected to the 

BLACK

 (or 

RED

) wire from the ceiling instead.]

 

* Wrap each wire connector separately with electrical 
tape as an extra safety measure.

 

This fan is remote control adaptable (remote control sold 
separately).

page 5

5. Fan Assembly. (cont.)

With the hanging bracket secured to the outlet box and able to 
support the fan, you are now ready to hang your fan. Grab the fan 
firmly with two hands. Slide downrod through opening in hanging 
bracket and let hanging ball rest on the hanging bracket. Turn the 
hanging ball slot until it lines up with the hanging bracket tab.

 
WARNING

: Failure to align slot in hanging ball with tab in hanging 

bracket may result in serious injury or death.

 
Tip

: Seek the help of another person to hold the stepladder in 

place and to lift the fan up to you once you are set on the ladder.

 

Find a secure attachment point (wood ceiling joist highly 
recommended) and secure safety cable. It will be necessary to 
use a heavy duty wood screw, washer and lock washer (not 
supplied) with the safety cable loop. If necessary, adjust the loop 
at the end of the safety cable. The loop at the end of the safety 
cable should just fit over the threads on the wood screw. 

Test 

safety cable by pulling on loose end of cable with pliers. If the safety 
cable slips, the loop must be adjusted tighter. 

Extra cable slack can 

be left in ceiling area. 

hanging bracket tab

motor housing

safety
cable

safety cable loop

wood ceiling
joist

wood screw

and washer

6. Wiring.

wire

connector

black

black

white

white

blue

black supply wire

ground
(green
or bare)

white supply wire

from

ceiling

from

fan

ground 
(green or bare)

*

hanging ball slot

Summary of Contents for Sloan SLN56

Page 1: ...pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 5 Canopy Assembly pg 6 Blade Assembly pg 6 Switch Housing Assembly pg 7 Testing Your Fan pg 7 Troubleshooting pg 8 Parts Replaceme...

Page 2: ...nsult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CUL Canada or UL USA listed and marked...

Page 3: ...k against parts inventory that all parts have been included 2 Parts Inventory a canopy 1 piece b hanging bracket 1 piece c downrod and hanging ball 1 piece d motor housing 1 piece e yoke cover 1 piece...

Page 4: ...tlet box be sure the outlet box is securely attached to the building structure and can support the full weight of the fan Ensure outlet box is clearly marked Suitable for Fan Support If not it must be...

Page 5: ...canopy cover in hardware pack Slide yoke cover canopy cover and canopy over downrod Refer to diagram 3 Note Canopy cover must be turned with black side toward the motor housing Thread safety cable an...

Page 6: ...lectrical tape as an extra safety measure This fan is remote control adaptable remote control sold separately page 5 5 Fan Assembly cont With the hanging bracket secured to the outlet box and able to...

Page 7: ...uce the risk of serious bodily injury DO NOT use power tools to assemble the blades If screws are overtightened blades may crack and break Time Saver Washers for blade screws can be set on each blade...

Page 8: ...e position diagram 4 fan will not operate Attach pull chain extension supplied or custom pull chain extension sold separately to the end of the pull chain diagram 1 diagram 2 diagram 3 diagram 4 switc...

Page 9: ...tmade We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY CRAFTMADE will repair or replace at no charge to the original purchaser any fan motor that f...

Reviews: