5. Fan Assembly. (cont.)
page 5
6. Wiring.
WARNING:
Turn off circuit breakers to current fixture
from breaker panel and be sure operating light switch
is turned to the OFF position.
CAUTION
:
Be sure outlet box is properly grounded and
that a ground wire (
GREEN
or Bare) is present.
Make sure all electrical connections comply with Local
Codes or Ordinances and the National Electrical Code. If
you are unfamiliar with electrical wiring or if the
house/building wires are different colors than those
referred to below, please use a qualified electrician.
Note
:
Excess lead wire length from the fan can be
cut to the desired length and then stripped.
When downrod is secured in place on the hanging
bracket, electrical wiring can be made as follows:
Connect
BLACK
and
BLUE
wire from fan to
BLACK
wire from ceiling with wire connector provided.
Connect
WHITE
wire from fan to
WHITE
wire from
ceiling with wire connector provided.
Connect all
GROUND
(
GREEN
) wires together from
fan to
BARE
/
GREEN
wire from ceiling with wire
connector provided.
* Wrap each wire connector separately with electrical
tape as an extra safety measure.
This fan is remote control adaptable (remote
control sold separately).
black
black
white
white
blue
black supply wire
ground
(green
or bare)
white supply wire
*
from ceiling
from fan
ground
(green or bare)
With the hanging bracket secured to the outlet box and
able to support the fan, you are now ready to hang your
fan. Grab the fan firmly with two hands. Slide downrod
through opening in hanging bracket and let hanging
ball rest on the hanging bracket. Turn the hanging ball
slot until it lines up with the hanging bracket tab.
WARNING
: Failure to align slot in hanging ball with tab
in hanging bracket may result in serious injury or death.
Tip
: Seek the help of another person to hold the
stepladder in place and to lift the fan up to you once
you are set on the ladder.
Find a secure attachment point (wood ceiling joist
highly recommended) and secure safety cable. It will be
necessary to use a heavy duty wood screw, washer and
lock washer (not supplied) with the safety cable loop.
Adjust safety cable length by loosening screw and nut
on safety cable vice. Adjust slack to a hand's length and
tighten nut on vice securely. The loop at the end of the
safety cable should just fit over the threads on the
wood screw.
Test safety cable by pulling on loose end
with pliers.
If cable slips, then vice and nut must be set
tighter. Extra cable slack can be left in ceiling area.
motor housing
wood
ceiling
joist
hanging ball slot
hanging bracket tab
safety cable
wood screw
and washer
safety cable loop