background image

page 5

With wider opening facing up, place housing ring over 

top

 of motor housing. Then, push housing ring down 

past top edge of motor housing.

Lift motor housing to mounting plate and then hang 
motor housing on j-hook on underside of mounting 
plate. (Use one of the 

non-slotted

 holes on the rim of the 

motor housing to do so.) This will allow motor housing to 
hang out of the way while wiring.

Tip

: Seek the help of another person to hold the 

stepladder in place and to lift the fan up to you once you 
are set on the ladder.

Find a secure attachment point (wood ceiling joist highly 
recommended) and secure safety cable. It will be 
necessary to use a heavy duty wood screw, washer and 
lock washer (not supplied) with the safety cable loop. If 
necessary, adjust the loop at the end of the safety cable. 
The loop at the end of the safety cable should just fit over 
the threads on the wood screw

. Test safety cable by 

pulling on loose end of cable with pliers. If the safety cable 
slips, the loop must be adjusted smaller. 

Extra cable slack 

can be left in ceiling area.

5. Preparation for Wiring.

wood

joist

safety

cable

loop

wood screw

and washer

safety

cable

non-slotted

hole

j-hook

motor housing

housing ring

6. Wiring.

(wiring for receiver)

white supply wire

black supply wire

black

black

white

blue

blue

white

from receiver

black

AC IN L

AC IN N

white

whit

e

ground (green

or bare)

from fan

from receiver

antenna

from ceiling

receiver

ground
(green or bare)

WARNING

: Turn off circuit breakers to current fixture 

from breaker panel and be sure switch is turned to the 
OFF position. 

CAUTION

Be sure outlet box is properly grounded and 

that a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code. If 
you are unfamiliar with electrical wiring or if the 
house/building wires are different colors than those 
referred to in the diagram to the right, please use a 
qualified electrician.

Note

Excess lead wire length from the fan can be cut 

to the desired length and then stripped.

Once motor housing has been temporarily hung on the 
j-hook on the mounting plate, wire the

 RECEIVER

 with 

wire connectors provided 

as shown in diagram at right.

Tip

: While you are wiring, keep in mind that wires must 

not obstruct receiver.

* Wrap each wire connector separately with electrical 
tape as an extra safety measure.

Gently insert receiver (flat side up) into mounting plate 
and carefully push wires and taped wire connectors into 
outlet box. Let antenna rest 

outside 

of mounting plate.

["Wiring" continued on next page.]

black

Summary of Contents for Revello REV52

Page 1: ...arts Inventory pg 3 Installation Preparation pg 4 Mounting Plate Installation pg 4 Preparation for Wiring pg 5 Wiring pgs 5 6 Fan Assembly pg 6 Blade Assembly pg 7 Light Kit Assembly pgs 7 8 Handheld...

Page 2: ...until the fan has come to a complete stop Note If using remote control with reverse capability reverse fan blade direction only when on LOW speed 9 Do not insert anything between the fan blades while...

Page 3: ...ry that all parts have been included 2 Parts Inventory a mounting plate 1 piece b housing ring 1 piece c motor housing 1 piece d wall plate 1 piece e remote control cover 1 piece f faceplate 3 pieces...

Page 4: ...on outer edge of mounting plate closest to the j hook and remove that screw Also remove screw on outer edge of mounting plate directly opposite the screw that was just removed Partially loosen the oth...

Page 5: ...sing ring 6 Wiring wiring for receiver white supply wire black supply wire black black white blue blue white from receiver black AC IN L AC IN N white white ground green or bare from fan from receiver...

Page 6: ...t of wall control Attach wall control to outlet box and secure with screws from original wall switch Attach wall plate included to wall control using 2 screws provided with the wall control wiring for...

Page 7: ...ck and break Time Saver Washers for blade attachment screws can be set on each screw prior to installing blades Locate 12 blade attachment screws and washers in hardware pack Slide a blade through one...

Page 8: ...urely Carefully arrange wiring within fitter plate Align slotted holes in LED light kit with loosened screws in fitter plate Twist LED light kit to lock Re insert screw that was previously removed and...

Page 9: ...art of remote control cover aligning posts in top of remote control cover with post holes in the bottom Refer to diagram 3 NOTE Make sure to align narrower ends of remote control cover before closing...

Page 10: ...n for up to 5 seconds Test fan speeds with the different fan speed buttons If the wall and or handheld remote control operate s all of the functions of the fan and light battery batteries has have bee...

Page 11: ...ates where prohibited Problem Fan fails to operate Solutions 1 Check wall switch to fan wall control 2 Check to be sure wall control optional use is wired properly 3 Check to be sure fan is wired prop...