page 7
6. Wiring.
WARNING
: Turn off circuit breakers to current
fixture from breaker panel and be sure switch
is turned to the OFF position.
CAUTION
:
Be sure outlet box is properly
grounded or that a ground wire (
GREEN
or
Bare) is present.
Make sure all electrical connections comply
with Local Codes or Ordinances and the
National Electrical Code. If you are unfamiliar
with electrical wiring or if the
house/building wires are different colors
than those referred to below, please use a
qualified electrician.
WARNING
: If using this fan in a
WET
location,
this fan must be connected to a supply circuit
that is protected by a Ground Fault Circuit
Interrupter (GFCI) to reduce the risk of
personal injury, electrical shock or death.
When fan is secured in place on the hanging
bracket, electrical wiring can be made as
follows:
Connect
BLACK
wire from fan to
BLACK
wire
from ceiling with wire connector provided.
Connect
WHITE
wire from fan to
WHITE
wire
from ceiling with wire connector provided.
Connect all
GROUND
(
GREEN
) wires together
from fan to
BARE
/
GREEN
wire from ceiling with
wire connector provided.
Since this fan does not come with a light kit,
you will need to cap off the
BLUE
wire with a
wire connector (
as shown with arrow in
diagram at right
).
NOTE
: If you elect to
purchase a light kit for the fan, the
BLUE
wire
from the fan must be connected to the
BLACK
wire from the ceiling instead.
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
This fan is remote control adaptable (remote
control sold separately).
wire
connector
black
black
white
white
blue
black supply wire
ground
(green
or bare)
white supply wire
from
ceiling
from fan
ground
(green or bare)
*