background image

5. Fan Assembly. (cont.)

page 6

With the hanging bracket secured to the outlet box 
and able to support the fan, you are now ready to 
hang your fan. Grab the fan firmly with two hands. 
Slide downrod through opening in hanging bracket 
and let hanging ball rest on the hanging bracket. 
Turn the hanging ball slot until it lines up with the 
hanging bracket tab.

WARNING

: Failure to align slot in hanging ball with 

tab in hanging bracket may result in serious injury 
or death.

Tip

: Seek the help of another person to hold the 

stepladder in place and to lift the fan up to you 
once you are set on the ladder.

6. Wiring.

WARNING

: Turn off circuit breakers to current fixture from 

breaker panel and be sure switch is turned to the OFF 
position.

CAUTION

Be sure outlet box is properly grounded and that a 

ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with Local Codes 
or Ordinances and the National Electrical Code. If you are 
unfamiliar with electrical wiring or if the house/building wires 
are different colors than those referred to in the instructions 
below, please use a qualified electrician.

Note

Excess lead wire length from the fan can be cut to the 

desired length and then stripped.

DANGER: 

If using this fan in a WET location, this fan must 

be connected to a supply circuit that is protected by a 
Ground Fault Circuit Interrupter (GFCI) to reduce the risk of 
personal injury, electrical shock or death.

When fan is secured in place on the hanging bracket, 
electrical wiring can be made as follows:
Connect 

BLACK

 and 

BLUE

 wires from fan to 

BLACK

 wire 

from ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from ceiling 

with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from fan to 

BARE

/

GREEN

 wire from ceiling with wire connector 

provided.

If you intend to control the fan light with a separate light 
switch connect 

BLUE

 wire from fan  to the 

BLACK

 (or 

RED

supply from the independent switch.

* Wrap each wire connector separately with electrical tape 
as an extra safety measure.

This fan is remote control adaptable (remote 
control sold separately). 

Note

: Only remote 

controls approved for WET locations can be 
used with this fan.

black supply wire

white supply wire

ground 
(green or bare)

*

black

black

white

white

blue

ground

 (green

or bare)

from ceiling

from fan

hanging ball slot

hanging bracket tab

motor housing

(wiring for fan)

Summary of Contents for Morrow Bay

Page 1: ...et Installation pg 4 Fan Assembly pgs 5 6 Wiring pg 6 Canopy Assembly pg 7 Blade Assembly pg 7 Light Kit Assembly pgs 8 9 Testing Your Fan pg 10 Troubleshooting pg 11 Warranty pg 11 Parts Replacement...

Page 2: ...switches for proper assembly 6 After installation is complete check that all connections are absolutely secure 7 After making electrical connections spliced conductors should be turned upward and pus...

Page 3: ...housing plate 1 piece o wire housing pre attached to switch housing plate 1 piece p decorative nut pre attached to switch housing plate 4 pieces q hardware packs page 3 a b d e c f g l i Carefully op...

Page 4: ...2 13m 76cm 30 inches Turn off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior t...

Page 5: ...yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously removed Tighten yoke set screws and nuts securely R...

Page 6: ...lified electrician Note Excess lead wire length from the fan can be cut to the desired length and then stripped DANGER If using this fan in a WET location this fan must be connected to a supply circui...

Page 7: ...ned blades may crack and break Time Saver Washers for blade screws can be set on each blade screw prior to installing blades Locate 12 blade attachment screws and washers in hardware pack Hold blade a...

Page 8: ...tor housing to female plug large from the light kit fitter Connect male plug small from the switch housing plate to female plug small from the light kit fitter Align slotted holes in light kit fitter...

Page 9: ...k or break Thread pull chains through corresponding holes in finial plate and center pull chain through hole in finial Tighten finial Note Do not overtighten finial as glass may crack or break Very ge...

Page 10: ...OT remove weatherproof cover from reverse switch Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season LEFT position in summer diagram...

Page 11: ...ect in material or workmanship Contact Craftmade Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to Craftmade We will repair or ship you a replacement fan a...

Page 12: ...Instalaci n el ctrica P g 6 Colocaci n de la cubierta decorativa P g 7 Colocaci n de las aspas P g 7 Instalaci n del juego de luz P gs 8 9 Verificaci n del funcionamiento del ventilador P g 10 Locali...

Page 13: ...ctrica o la muerte 5 Los diagramas el ctricos son nicamente para referencia 6 Despu s de haber terminado la instalaci n asegurarse de que todas las conexiones est n totalmente seguras 7 Despu s de hab...

Page 14: ...ra el aspa 4 unidades h aspa 4 unidades i conectador para el juego de luz 1 unidad j arandela roscada fijada de antemano al conectador para el juego de luz 1 unidad k placa del adorno con rosca fijada...

Page 15: ...ambres y cinta aisladora Apagar los cortacircuitos en el panel de electricidad que suplen corriente a la caja de salida y asegurarse de que el interruptor de luz est APAGADO ADVERTENCIA el no desconec...

Page 16: ...cuello y la tuerca completamente Referirse al diagrama 2 Deslizar la cubierta del cuello y la cubierta decorativa por el tubo Referirse al diagrama 3 Pasar los cables por la bola que sirve para colgar...

Page 17: ...es diferentes a los cuales se refieren a continuaci n favor de buscar un electricista calificado Nota si la longitud del alambrado que sale del ventilador es demasiado se puede cortarlo al largo desea...

Page 18: ...portes de pl stico guardar los tornillos para el brazo para el aspa y las arandelas de seguridad para asegurar los brazos para el aspa Alinear los agujeros de uno de los brazos para las aspas con los...

Page 19: ...enchufe macho peque o de la placa de la caja de encendido con el enchufe hembra peque o del conectador para el juego de luz Alinear los agujeros con ranura en el conectador para el juego de luz con lo...

Page 20: ...asiado ya que el vidrio se puede rajar o romper Pasar las cadenas de encendido por los agujeros correspondientes en la placa del adorno con rosca y pasar la cadena de encendido de en medio por el aguj...

Page 21: ...nte Importante no quitar la cubierta a prueba de la intemperie del interruptor de reversa Apagar el ventilador completamente antes de mover el interruptor de reversa Regularlo para que se circule bien...

Page 22: ...ara uso interior con las siguientes condiciones GARANTIA DE 1 A O CRAFTMADE reemplazar o reparar cualquier ventilador que tenga funcionamiento deficiente debido a defectos en los materiales o trabajo...

Reviews: