Loosen the screws in the 2 slotted holes in the light 
kit fitter (located on the underside of the motor 
housing) and remove the other screw. Twist light kit 
fitter and pull down carefully on light kit fitter in 
order to remove. 
[

Note

: Molex plugs MUST be disconnected 

BEFORE

 

removing the light kit fitter from the motor 
housing. Molex plugs may be disconnected by 
simply pulling them apart.]

Time Saver

: Washers for blade screws can be set on 

each blade screw prior to installing blades.

Locate 12 blade attachment screws and washers in 
hardware pack. Slide a blade through one of the 
narrow, rectangular openings on motor housing, 
aligning holes in blade with holes in blade arm 
(

located on INSIDE of the underside of the motor 

housing

)--

refer to drawing at right

. Insert 3 blade 

attachment screws (along with washers) and then 
tighten screws securely with a Phillips screwdriver. 
Repeat procedure for each remaining blade.

Note

: Tighten blade arm screws twice a year.

8. Blade Assembly.

9. Light Kit Assembly.

Re-attach molex plugs by connecting 

BLACK

 wire 

from motor housing to 

BLACK

 wire from light kit 

fitter and 

WHITE

 wire from motor housing to 

WHITE

  wire from light kit fitter. Be sure that molex 

connections snap together completely.

Carefully arrange wiring within the fitter plate. Align 
slotted holes in the light kit fitter with loosened 
screws in fitter plate--

be careful not to pinch wires or 

molex connections between the light kit fitter and the 
fitter plate

.  Twist  light kit fitter to lock. Re-insert 

screw that was previously removed.  Tighten all 3 
screws to secure light kit fitter. 

fitter plate

molex
connections

light kit fitter

motor

housing

blade

blade attachment

screws and washers

molex
connections

Summary of Contents for MN44FB4

Page 1: ...ng Process Activating Code pg 8 Wall Control Operation pg 9 Remote Control Operation pg 9 Testing Your Fan pg 9 Troubleshooting pg 10 Warranty pg 10 Parts Replacement pg 10 net weight of fan 13 45 lb...

Page 2: ...12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference...

Page 3: ...cluded IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety m a canopy 1 piece b hanging bracket pre attached to canopy 1 piece c 6in downrod and hanging...

Page 4: ...to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet box is securely attached to the building structure and can support the...

Page 5: ...cal wires this will keep the wires together when threading them through the downrod Loosen yoke set screws and nut at top of motor housing Remove pin and clip from downrod if you have not already done...

Page 6: ...od screw washer and lock washer not supplied with the safety cable loop Extra cable slack can be left in ceiling area yoke cover safety cable loop canopy wood ceiling joist hanging ball slot hanging b...

Page 7: ...ide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance wi...

Page 8: ...t right Insert 3 blade attachment screws along with washers and then tighten screws securely with a Phillips screwdriver Repeat procedure for each remaining blade Note Tighten blade arm screws twice a...

Page 9: ...eivers or fans If this is not desired turn wall switch off to any other programmable receiver or fan Remove battery cover on back side of remote control transmitter Use a ballpoint pen or a small scre...

Page 10: ...olding it down for 1 second Test fan speeds with the different fan speed buttons diagram 1 If the remote control operates all of the functions of the fan battery has been installed correctly If the wa...

Page 11: ...1 Use the balancing kit in one of the hardware packs If no blade balancing kit is provided please call Customer Support 1 800 486 4892 to request one 2 Check to be sure set screw s on motor housing y...

Page 12: ...el c digo P g 8 Funcionamiento del control de pared P g 9 Funcionamiento del control remoto P g 9 Verificaci n del funcionamiento del ventilador P g 9 Localizaci n de fallas P g 10 Garant a P g 10 Pi...

Page 13: ...el cable de la casa es superior al 12 o hay m s de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informarse...

Page 14: ...24cm y bola que sirve para colgar con perno y clavija 1 unidad d cubierta del cuello 1 unidad e bastidor del motor 1 unidad f control de pared 2 unidades distintas g receptor del control remoto 1 uni...

Page 15: ...uede tener por resultado lesiones graves Quitar el aparato existente ADVERTENCIA Si utiliza una caja de salida existente asegurarse de que la caja de salida est firmemente conectada a la estructura de...

Page 16: ...juntos al pasarlos por el tubo Aflojar los tornillos de fijaci n del cuello y la tuerca en la parte superior del bastidor del motor Quitar el perno y la clavija del tubo si todav a no se hace Pasar e...

Page 17: ...trabajos pesados arandela y arandela de seguridad no provistos en el bucle del cable de seguridad Se puede poner el cable en exceso en el rea del techo cubierta decorativa viga de madera parte salient...

Page 18: ...cuerdo con la Parte 15 de las Reglas de la FCC Se concibieron estos l mites para proveer protecci n razonable contra la interferencia adversa en una instalaci n residencial Este equipo produce usa y p...

Page 19: ...con las arandelas y luego apretar los tornillos bien con un destornillador de estrella Phillips Repetir el procedimiento con las dem s aspas Nota Apretar los tornillos para los brazos para las aspas d...

Page 20: ...ventiladores Si no desea hacer esto apagar el interruptor de cualquier otro receptor o ventilador programable Quitar la tapa de la bater a en la parte de atr s del transmisor del control remoto Usar...

Page 21: ...NDIDO con el bot n en el control remoto Poner a prueba el funcionamiento del reductor de luz oprimiendo el bot n por m s de 2 segundos Verificar las velocidades del ventilador con los diferentes boton...

Page 22: ...veriguar que hay bater a en el control de pared verificar si a n sirve la bater a Problema El ventilador se tambalea Soluciones 1 Usar el juego para balancear las aspas incluido en uno de los paquetes...

Reviews: