6. Wiring.

WARNING

: Turn off circuit breakers to current 

fixture from breaker panel and be sure switch is 
turned to the OFF position.

 
CAUTION

Be sure outlet box is grounded properly 

and that a ground wire (

GREEN

 or Bare) is present.

 

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code. 
If you are unfamiliar with electrical wiring or if the 
house/building wires are different colors than those 
referred to below, please use a qualified electrician.

 

Once fan has been temporarily hung on the 
mounting plate, electrical wiring can be made 
as follows:
Connect 

BLACK

 and 

BLUE 

wires from fan to 

BLACK

 

wire from ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire 

from ceiling with wire connector provided.
Connect 

GROUND 

(

GREEN

) wire from mounting 

plate to 

BARE

/

GREEN

 wire from ceiling with wire 

connector provided.
If you intend to control the fan light with a separate 
light switch connect 

BLUE

 wire from fan  to the 

BLACK

 (or 

RED

) supply from the independent 

switch.

* Wrap each wire connector separately with 
electrical tape as an extra safety measure.

Lift motor assembly to mounting plate. Hang 
motor assembly on j-hook, using oval hole 
located on plate at top of motor assembly. This 
will allow motor assembly to hang out of the 
way while wiring.

Tip

: Seek the help of another person to hold the 

stepladder in place and to lift the fan up to you 
once you are set on the ladder.

 

Find a secure attachment point (wood ceiling 
joist highly recommended) and secure safety 
cable. It will be necessary to use a heavy duty 
wood screw, washer and lock washer (not 
supplied) with the safety cable loop. If necessary, 
adjust the loop at the end of the safety cable. 
The loop at the end of the safety cable should 
just fit over the threads on the wood screw

.

 

Test 

safety cable by pulling on loose end of cable with 
pliers. If the safety cable slips, the loop must be 
adjusted smaller. 

Extra cable slack can be left in 

ceiling area.

5. Preparation for Wiring.

This fan is remote control adaptable (remote 
control sold separately). 

wood joist

safety

cable

loop

wood screw

and washer

safety

cable

j-hook

motor assembly

mounting plate

oval
hole

motor assembly

mounting
plate

*

WHITE

WHITE

BLACK

BLACK

BLUE

GREEN

wire

connector

(supply circuit)

WHITE

BLACK

outlet

box

GROUND 

(GREEN 

OR BARE)

Summary of Contents for Merit MER52

Page 1: ...2641 Merit page 1 Table of Contents Safety Tips pg 2 Unpacking Your Fan pg 3 Parts Inventory pg 3 Installation Preparation pg 4 Mounting Plate Installation pg 4 Preparation for Wiring pg 5 Wiring pg 5...

Page 2: ...ng remote control with reverse capability reverse fan blade direction only when on LOW speed 9 Do not insert anything between the fan blades while they are rotating WARNING To reduce the risk of perso...

Page 3: ...s fan need to be returned for repairs Check against parts inventory that all parts have been included 2 Parts Inventory a mounting plate 1 piece b motor housing 1 piece c motor assembly 1 piece d cent...

Page 4: ...vided with new or original outlet box Pull electrical wiring from outlet box through center hole in the mounting plate Note It is very important that you use the proper hardware when installing the mo...

Page 5: ...tor separately with electrical tape as an extra safety measure Lift motor assembly to mounting plate Hang motor assembly on j hook using oval hole located on plate at top of motor assembly This will a...

Page 6: ...ge of mounting plate Twist motor housing to the RIGHT to lock Refer to diagram 2 WARNING It is important that you make sure to turn the motor housing all the way to the right to ensure that the motor...

Page 7: ...ly to come through hole in middle of fitter plate Twist fitter plate to lock Re insert screw that was previously removed and securely tighten all 3 screws with a Phillips screwdriver diagram 1 Remove...

Page 8: ...Customer Service Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season LEFT position in summer diagram 2 RIGHT position in winter diag...

Page 9: ...any fan which has faulty performance due to a defect in material or workmanship Contact Craftmade Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to Craftm...

Page 10: ...des pi ces p 3 Pr paration de l installation p 4 Installation de la plaque de montage p 4 Pr paration du c blage p 5 C blage p 5 Assemblage du ventilateur p 6 Assemblage et montage des pales p 7 Asse...

Page 11: ...du ventilateur causera un bourdonnement fort du ventilateur Remarque Ce ventilateur convient une utilisation avec t l commande 8 N utilisez pas l interrupteur d inversion avant que le ventilateur ne s...

Page 12: ...cas o le ventilateur aurait besoin d tre retourn pour des r parations V rifiez que toutes les pi ces figurant sur l inventaire sont pr sentes 2 Inventaire des pi ces a plaque de montage 1 pi ce b cart...

Page 13: ...uspension la bo te de sortie l aide des vis rondelles ressort et rondelles plates originales fournies avec la bo te de sortie de courant neuve ou originale Passer les fils lectriques de la bo te de so...

Page 14: ...lmis laterre VERToud nud estpr sent Assurez vousquetouslesbranchements lectriquessont conformesauxcodesour glementslocauxetauCodenational del lectricit Encasdedoutequant lar alisationduc blage lectriq...

Page 15: ...sur le bord de la plaque de montage Tournez le carter moteur vers la DROITE pour le verrouiller sch ma 2 AVERTISSEMENT il est important que vous assuriez de tourner le carter moteur compl tement vers...

Page 16: ...eur permettant la fiche m le du groupe moteur de passer par le trou au milieu de la plaque de montage Tournez la plaque de montage pour verrouiller R ins rez la vis pr c demment retir e et serrez ferm...

Page 17: ...nage pour r soudre tout probl me avant de communiquer avec le service la client le teignez compl tement le ventilateur avant de d placer l interrupteur d inversion R glez l interrupteur d inversion po...

Page 18: ...ons Cette garantie n est pas applicable lorsque des dommages caus s par un abus m canique physique lectrique ou un abus d l eau entra nent la d faillance La d t rioration des finis ou d autres pi ces...

Page 19: ...a instalaci n P g 4 Instalaci n de la placa de montaje P g 4 Preparaci n para la instalaci n el ctrica P g 5 Instalaci n el ctrica P g 5 Instalaci n del ventilador P g 6 Colocaci n de las aspas P g 7...

Page 20: ...causar un zumbido recio del ventilador Nota Este ventilador s sirve para usar con control remoto 8 No utilizar el interruptor de reversa hasta que el ventilador se haya parado completamente Nota Si se...

Page 21: ...Comprobar las piezas del ventilador con el inventario de piezas y verificar que se incluyeron todas RECORDATORIO IMPORTANTE Se tienen que utilizar las piezas provistas con este ventilador para una ins...

Page 22: ...as planas de su nueva o existente caja de salida Pasar el alambrado el ctrico los cables de la caja de salida por el agujero de en medio de la placa de montaje Nota Es muy importante usar los art culo...

Page 23: ...lador al conductor NEGRO o ROJO que corresponde al interruptor independiente Como una medida de seguridad adicional envolver cada conector para cable por separado con cinta aisladora BLANCO BLANCO NEG...

Page 24: ...los 4 postes en el borde de la placa de montaje Gire el bastidor del motor hacia la DERECHA para cerrarlo Referirse al diagrama 2 ADVERTENCIA Es importante que se asegure de girar el bastidor del moto...

Page 25: ...xi n con los tornillos aflojados en la placa del motor dejando que el enchufe macho del bastidor del motor pase por el agujero de en medio en la placa de conexi n Girar la placa de conexi n para cerra...

Page 26: ...ci n Localizaci n de fallas Apagar el ventilador completamente antes de mover el interruptor de reversa Regularlo para que circule bien el aire dependiendo de las estaciones del a o posici n IZQUIERDA...

Page 27: ...grupo familiar para uso interior con las siguientes condiciones GARANTIA DE 1 A O CRAFTMADE reemplazar o reparar cualquier ventilador que tenga funcionamiento deficiente debido a defectos en los mater...

Reviews: