background image

page 10

1

--Fan 

SPEED

 control button(s):

          

Use to control the ceiling fan speed 1-6

2

--Fan

 OFF

 button: 

 

 

    Use to turn the fan off

3

--

REVERSE

 function button: 

    Use to control fan direction

4

--

LIGHTING

 button:       

 

    Use to control down-light and up-light (if applicable)

5

--

ON

/

OFF

 slider switch:  

 

    [Wall control only] Use to turn wall control on or off

IMPORTANT:

Handheld remote 
control and wall
control must be
SYNCHRONIZED with
fan in order to
properly function.

handheld

remote control

wall control

4

3

1

5

I

OFF

ON

II

III

IV

V

VI

2

14. Remote/Wall Control Operation.

I

II

IV

VI

III

V

4

1

2

3

15. Testing Your Fan.

It is recommended that you test fan before finalizing installation. 
Restore power from circuit box and light switch (if applicable). Test wall 
control (optional installation) by locating ON/OFF slider switch on wall 
control, then set to the ON position. Test light function and test fan 
speeds. Locate handheld remote control. Test fan speeds with the 
different fan speed buttons (

I - VI

) on handheld remote control. Test 

the light ON/OFF function by pressing the         button. If the remote 
control operates all of the functions of the fan/light, battery has been 
installed correctly. If the wall and/or remote control do (does) not 
operate all of the fan/light functions, refer to "Troubleshooting" section 
to solve any issues before contacting Customer Service.

Fan 

must

 be on LOW 

before

 setting the fan in reverse. Use          button 

to recirculate air depending on the season. A ceiling fan will allow you 
to raise your thermostat setting in summer and lower your thermostat 
setting in winter without feeling a difference in your comfort.

NOTE

: If the wall control/handheld remote control interferes with other 

appliances, activate a new code on the wall control/ handheld remote 
control by 

turning the power off first

. Go back to the instructions for 

the SET button in Section 13 (page 9).

IMPORTANT

: Handheld remote control and wall control must be 

synchronized with fan in order to properly function.

I

II

IV

VI

III

V

IMPORTANT

:  

The Automated Learning Process takes approximately 5 minutes to complete.

 Please 

leave the fan “ON”

 for the duration of the 5-minute programming and 

do NOT use

 

the 

remote control or turn the power off

 during this time.

 

 

    The fan will 

cycle through ALL SIX (6) speeds in forward and reverse

 and will 

then stop 

automatically

 after the learning process is complete.

Summary of Contents for Cortana CR52-LED

Page 1: ...mbly pg 7 Final Installation pg 8 Handheld Remote Control Assembly pg 8 Automated Learning Process Activating Code pg 9 Remote Wall Control Operation pg 10 Testing Your Fan pg 10 Troubleshooting pg 11 Parts Replacement pg 11 Warranty pg 11 Installation Guide PRINTED IN CHINA For Model CR52 LED net weight of fan 26 lb 11 8 kg E192641 Cortana WARNING DC Motor will not operate until blades are instal...

Page 2: ...not use this fan with any solid state speed control device or control fan speed with a full range dimmer switch Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan 8 Do not operate the reverse switch until the fan has come to a complete stop Note If using remote control with reverse capability reverse fan blade direction only when on LOW speed 9 Do not in...

Page 3: ... faceplate 3 pieces s hardware packs Blade drawings in this manual are representative only page 2 1 Unpacking Your Fan Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check against parts inventory that all pa...

Page 4: ...d electrical tape blade edge Turn off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet box is securely attached to the building structure and can supp...

Page 5: ...ously removed Tighten yoke set screws and nuts securely Refer to diagram 2 Locate canopy cover in hardware pack Slide yoke cover scroll arm support wide end up downrod accessory wider end down canopy cover shiny side down and canopy over the downrod Refer to diagram 3 From top of motor housing use sockets located inside of motor housing to install 3 candelabra base 4 watt LED bulbs included Refer ...

Page 6: ...ng your fan Grab the fan firmly with two hands Slide downrod through opening in hanging bracket and let hanging ball rest on the hanging bracket Turn the hanging ball slot until it lines up with the hanging bracket tab WARNING Failure to align slot in hanging ball with tab in hanging bracket may result in serious injury or death Tip Seek the help of another person to hold the stepladder in place a...

Page 7: ...radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna In...

Page 8: ...ock washers from underside of motor NOTE Use slot located on motor plate for access to blade arm screws with screwdriver Align blade arm holes with motor screw holes and attach blade arm with blade arm screws lock washers Before securing screws permanently repeat with remaining blade arms Securely tighten all screws IMPORTANT Tighten blade arm screws twice a year blade arm 9 Canopy Assembly screw ...

Page 9: ...need to use a different type of bulb sold separately and the switch must be moved to the ON position ON Refer to diagram 2 Align holes in wall control with posts located on inside of TOP part of remote control cover and press together firmly Place wall control into BOTTOM part of remote control cover aligning posts in top of remote control cover with post holes in the bottom Refer to diagram 3 NOT...

Page 10: ...st the light and fan functions to confirm the learning process is complete see Section 15 on the following page Select a faceplate almond or white and press firmly onto front of wall control that was previously installed to the outlet box on the wall Refer to diagram 1 Attach black faceplate to front of handheld remote control press down firmly Refer to diagram 2 CAUTION Store the handheld remote ...

Page 11: ...operates all of the functions of the fan light battery has been installed correctly If the wall and or remote control do does not operate all of the fan light functions refer to Troubleshooting section to solve any issues before contacting Customer Service Fan must be on LOW before setting the fan in reverse Use button to recirculate air depending on the season A ceiling fan will allow you to rais...

Page 12: ...ousehold purchaser for indoor use under the following provisions 1 YEAR WARRANTY CRAFTMADE will replace or repair any fan which has faulty performance due to a defect in material or workmanship Contact Craftmade Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to Craftmade We will repair or ship you a replacement fan and we will pay the return shipping co...

Page 13: ...eado Pág 5 Instalación eléctrica Pág 6 Colocación de la cubierta decorativa Pág 7 Colocación de las aspas Pág 7 Instalación final Pág 8 Ensamblaje del control remoto de mano Pág 8 Proceso de aprendizaje automático Activar el código Pág 9 Funcionamiento del control remoto de pared Pág 10 Verificación del funcionamiento del ventilador Pág 10 Localización de fallas Pág 11 Piezas de repuesto Pág 11 Ga...

Page 14: ...rar con el conductor a tierra a un lado y el conductor a tierra del equipo al lado opuesto ADVERTENCIA Para reducir el riesgo de incendio o una descarga eléctrica no usar el ventilador con ningún control de velocidad de estado sólido ni controlar la velocidad del ventilador con un interruptor con reductor de luz de gama completa El usar un interruptor con reductor de luz de gama completa para cont...

Page 15: ...ca 1 unidad r tapa 3 unidades s paquetes de artículos de ferretería Los dibujos del aspa en este manual son representativos únicamente 1 Desempaquetado del ventilador Abrir el empaque cuidadosamente Sacar los artículos del embalaje Sacar el motor y ponerlo en una alfombra o en el embalaje para evitar rayar el acabado Guardar la caja de cartón o el empaquetamiento original en caso de que tenga que ...

Page 16: ...corriente a la caja de salida y asegurarse de que el interruptor de luz esté APAGADO ADVERTENCIA El no desconectar el suministro de fuerza antes de la instalación puede tener por resultado lesiones graves Quitar el aparato existente ADVERTENCIA Si utiliza una caja de salida existente asegurarse de que la caja de salida esté firmemente conectada a la estructura del edificio y que sea capaz de soste...

Page 17: ...rca completamente Referirse al diagrama 2 Localizar la tapa de la cubierta decorativa en uno de los paquetes de artículos de ferretería Deslizar la cubierta del cuello el soporte de los brazos con volutas con el extremo ancho hacia arriba el accesorio del tubo con el extremo más ancho hacia abajo la tapa de la cubierta decorativa con el lado brillante hacia abajo y la cubierta decorativa por el tu...

Page 18: ...Agarrar el ventilador firmemente con las dos manos Deslizar el tubo por la abertura del soporte de montaje y dejar que se detenga la bola en el soporte de montaje Girar la bola que sirve para colgar hasta que la ranura de la bola se alinee con la parte saliente del soporte de montaje ADVERTENCIA El no alinear la ranura en la bola que sirve para colgar con la parte saliente del soporte de montaje p...

Page 19: ...causar interferencia adversa en la radiocomunicación Sin embargo no hay ninguna garantía de que no habrá interferencia en una instalación en particular Si este equipo sí causa interferencia adversa en la recepción de radio o televisión que se puede determinar apagando y prendiendo el equipo se le urge al usuario a intentar rectificar la interferencia tomando una o más de las medidas que siguen Ori...

Page 20: ...l acceso a los agujeros en el motor con el destornillador Alinear los agujeros de uno de los brazos para las aspas con los agujeros para los tornillos en el motor y fijar el brazo para el aspa con arandelas de seguridad y tornillos para el brazo para el aspa Antes de apretar los tornillos bien repetir el mismo procedimiento con los demás brazos para las aspas Apretar bien todos los tornillos IMPOR...

Page 21: ...terruptor a la posición de ENCENDIDO ON Referirse al diagrama 2 Alinear los agujeros en el control de pared con los postes que se encuentran adentro de la parte SUPERIOR de la cubierta del control remoto y apretar fijamente Colocar el control de pared dentro de la parte INFERIOR de la cubierta del control remoto alineando los postes en la parte superior de la cubierta del control remoto con los ag...

Page 22: ...uz y ventilador para confirmar que se ha terminado el proceso de aprendizaje ver la sección 15 en la página siguiente Escoger una tapa color almendra o blanco y apretarla firmemente en la parte delantera del control de pared que se instaló anteriormente en la caja de salida de la pared Referirse al diagrama 1 Fijar la tapa negra a la parte delantera del control remoto de mano apretar la tapa firme...

Page 23: ...o interfiere con otros aparatos activar un código nuevo en el control de pared control remoto de mano cortando la corriente primero Repetir las instrucciones que se refieren al botón SET de la sección 13 página 9 IMPORTANTE Hay que sincronizar el control remoto de mano y el control de pared con el ventilador para que funcionen correctamente página 10 control remoto de mano control de pared 1 Botón...

Page 24: ...aves GARANTÍA LIMITADA DE POR VIDA DE CRAFTMADE CRAFTMADE garantiza este ventilador al comprador original de grupo familiar para uso interior con las siguientes condiciones GARANTÍA DE 1 AÑO CRAFTMADE reemplazará o reparará cualquier ventilador que tenga funcionamiento deficiente debido a defectos en los materiales o trabajo manual Comunicarse con el Servicio al cliente de CRAFTMADE al 1 800 486 4...