Craftmade CES209 Installation Manual Download Page 6

page 5

6. Wiring.

WARNING

: Turn off circuit breakers to current fixture 

from breaker panel and be sure switch is turned to the 
OFF position.

CAUTION

Be sure outlet box is properly grounded and 

that a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code. If 
you are unfamiliar with electrical wiring or if the 
house/building wires are different colors than those 
referred to below, please use a qualified electrician.

Note: 

Excess lead wire length from the fan can be cut to 

the desired length and then stripped.

When downrod is secured in place on the hanging 
bracket, electrical wiring can be made as follows:
Connect 

BLACK 

and

 BLUE

 wires from fan to 

BLACK

 

wire from ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from 

ceiling with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from fan 

to 

BARE

/

GREEN

 wire from ceiling with wire connector 

provided.

If you intend to control the fan light with a separate 
light switch, connect 

BLUE

 wire from fan to the 

BLACK

 

(or 

RED

) supply from the independent switch. 

* Wrap each wire connector separately with electrical 
tape as an extra safety measure.

wire

connector

black

white

black supply wire

ground
(green
or bare)

white supply wire

ground 
(green or bare)

*

5. Fan Assembly. (cont.)

With the hanging bracket secured to the outlet box and 
able to support the fan, you are now ready to hang your fan. 
Grab the fan firmly with two hands. Slide downrod through 
opening in hanging bracket and let hanging ball rest on the 
hanging bracket. Turn the hanging ball slot until it lines up 
with the hanging bracket tab.

WARNING

: Failure to align slot in hanging ball with tab in 

hanging bracket may result in serious injury or death.

Tip:

 Seek the help of another person to hold the stepladder 

in place and to help lift the fan up to you once you are set 
on the ladder. 

Find a secure attachment point (wood ceiling joist highly 
recommended) and secure safety cable. It will be necessary 
to use a heavy duty wood screw, washer and lock washer 
(not supplied) with the safety cable loop. Adjust safety cable 
length by loosening screw and nut on safety cable vice. 
Adjust slack to a hand's length and tighten nut on vice 
securely. The loop at the end of the safety cable should just 
fit over the threads on the wood screw. 

Test safety cable by 

pulling on loose end with pliers. 

If cable slips, then vice and 

nut must be set tighter. Extra cable slack can be left in 
ceiling area. 

motor housing

safety cable

hanging ball slot

wood ceiling joist

wood screw

and washer

safety cable loop

This fan is remote control adaptable
(remote control sold separately).

hanging bracket tab

black

white

blue

from fan

from

ceiling

vice

Summary of Contents for CES209

Page 1: ...king Your Fan pg 2 Parts Inventory pg 2 Installation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 5 Canopy Assembly pg 6 Blade Assembly pg 6 Light Kit Assembly pg 7 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty pg 9 For Model CES209 Installation Guide Pro Energy Saver 209 sold separately ...

Page 2: ...e to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only 6 After installation is complete check that all connections are absolutely secure 7 After making electrical connections spliced conductors should be turned upward and pushed carefully up into the outlet box The wires should be spread apart ...

Page 3: ...ng Your Fan Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check against parts inventory that all parts have been included IMPORTANT REMINDER You must use the parts provided with this fan for proper installa...

Page 4: ...nd the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support the fan page 3 ON OFF ON OFF hanging bracket spring washers outlet box screws flat washers 3 Installation Preparation To prevent personal injury and damage ensure that the hanging location allows the blades a cleara...

Page 5: ... slack from the upper end of the downrod Refer to diagram 2 Thread downrod into the motor housing yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously removed Tighten yoke set screws and nuts securely Refer to diagram 2 Slide canopy over downrod Refer to diagram 3 Thread safety cable and wires through h...

Page 6: ...green or bare white supply wire ground green or bare 5 Fan Assembly cont With the hanging bracket secured to the outlet box and able to support the fan you are now ready to hang your fan Grab the fan firmly with two hands Slide downrod through opening in hanging bracket and let hanging ball rest on the hanging bracket Turn the hanging ball slot until it lines up with the hanging bracket tab WARNIN...

Page 7: ...pack Hold blade arm up to blade and align holes Insert 3 blade attachment screws along with washers with fingers first and then tighten screws securely with a Phillips screwdriver Repeat for the remaining blades Remove blade arm screws and lock washers from underside of motor If plastic motor locks are installed with blade arm screws discard plastic motor locks save blade arm screws and lock washe...

Page 8: ...t align with the reverse switch on the switch housing for the proper fit Re insert screws that were previously removed and tighten all 3 screws securely with a Phillips screwdriver To attach glass shade align grooves on glass shade with nodules on inside of light kit fitter and push up gently on glass shade Then turn glass shade to the RIGHT clockwise until it no longer turns NOTE Pull down VERY G...

Page 9: ...re contacting Customer Service Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season DOWN position in summer diagram 2 UP position in winter diagram 3 A ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort IMPORTANT Reverse switc...

Page 10: ...haser shall be responsible for all costs incurred in the removal reinstallation and shipping of the product for repairs This warranty does not apply when damage from mechanical physical electrical or water abuse results in causing the malfunction Deterioration of finishes or other parts due to time or exposure to salt air is specifically exempted under this warranty Neither Craftmade nor the manuf...

Page 11: ... ventilador Págs 4 5 Instalación eléctrica Pág 5 Colocación de la cubierta decorativa Pág 6 Colocación de las aspas Pág 6 Instalación del juego de luz Pág 7 Verificación del funcionamiento del ventilador Pág 8 Localización de fallas Pág 9 Piezas de repuesto Pág 9 Garantía Pág 9 Guía de instalación IMPRESO EN CHINA Para modelo CES209 LEER ESTAS INSTRUCCIONES Y GUARDARLAS PARA UTILIZACION FUTURA 400...

Page 12: ...alibre del cable de la casa es superior al 12 o hay más de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informarse sobre el tamaño correcto de conectores para cable que se debe usar 5 Los diagramas eléctricos son únicamente para referencia 6 Después de haber terminado la instalación asegurarse de que todas...

Page 13: ...l empaque cuidadosamente Sacar los artículos del embalaje Sacar el motor y ponerlo en una alfombra o en el embalaje para evitar rayar el acabado Guardar la caja de cartón o el empaquetamiento original en caso de que tenga que mandar el ventilador para alguna reparación Comprobar las piezas del ventilador con el inventario de piezas y verificar que se incluyeron todas 2 Inventario de piezas RECORDA...

Page 14: ...los cortacircuitos en el panel de electricidad que suplen corriente a la caja de salida y asegurarse de que el interruptor de luz esté APAGADO ADVERTENCIA El no desconectar el suministro de fuerza antes de la instalación puede tener por resultado lesiones graves Quitar el aparato existente ADVERTENCIA Si utiliza una caja de salida existente asegurarse de que la caja de salida esté firmemente conec...

Page 15: ...sta alinearse los agujeros para el perno y la clavija en el tubo con los del cuello asegurarse de que no se tuerzan los cables Volver a introducir el perno y la clavija que se quitaron anteriormente Apretar los tornillos de fijación del cuello y la tuerca completamente Referirse al diagrama 2 Deslizar la cubierta decorativa por el tubo Referirse al diagrama 3 Pasar los cables y el cable de segurid...

Page 16: ...egro del ventilador del techo blanco azul alambre conductor negro alambre conductor blanco blanco negro ADVERTENCIA Apagar los cortacircuitos en el panel de electricidad que suplen corriente a la caja de salida y asegurarse de que el interruptor de luz esté APAGADO PRECAUCIÓN Asegurarse de que la caja de salida esté conectada a tierra como es debido y que exista un conductor a tierra VERDE o pelad...

Page 17: ... para alinear los agujeros Introducir 3 tornillos para fijar las aspas junto con las arandelas con los dedos primero y luego apretarlos bien con un destornillador de estrella Phillips Repetir el procedimiento con las demás aspas Sacar los tornillos para los brazos para el aspa y las arandelas de seguridad del lado inferior del motor Si se han instalado soportes de plástico con los tornillos para e...

Page 18: ...mente arreglar el cableado dentro de la cubierta de la caja de encendido Alinear los agujeros en la cubierta de la caja de encendido con los agujeros en la caja de encendido Nota La abertura en el borde superior de la cubierta de la caja de encendido debe alinearse con el interruptor de reversa en la caja de encendido para que se ajuste bien Volver a introducir los tornillos que se quitaron anteri...

Page 19: ... ventilador y o la luz no funciona favor de referirse a la sección Localización de fallas para resolver cualquier asunto antes de comunicarse con el Servicio al cliente Apagar el ventilador completamente antes de mover el interruptor de reversa Regularlo para que circule bien el aire dependiendo de las estaciones del año posición ABAJO en verano diagrama 2 posición ARRIBA en invierno diagrama 3 Un...

Page 20: ...idos en sacar reinstalar y enviar el producto para reparación Esta garantía no se aplica cuando el ventilador tenga daños por abuso mecánico físico eléctrico o por agua resultando en su mal funcionamiento Se exenta especí ficamente el deterioro en el acabado u otras partes debido al tiempo o exposición al aire marino bajo esta garantía Ni Craftmade ni el fabricante se harán responsables por lo que...

Reviews: