LED Indication

Operating Buttons

Optional Surface Mount Back Box

Standard UK Fixing Centres
for electrical switches.

I

NSTALLATION

 & S

ET

 

UP

Set up

The unit is supplied set up as a standard hold up device

, ready to be fitted without any

further configuration.

2

O

PERATION

+12v

0v

SPARE

EOL C

onnec

tions

NC2

NC3

NC1

NO

COM

A/T1

A/T2

S

elec

table EOL

Confirmation Relay

Plus version only

Shown with optional

customer fitted EOL

1.        12v + Supply in
2.         0v - Supply in
3.        NC Relay for alarm
4.        NO Relay for alarm
5.        COM Relay for alarm
6.        Anti-Tamper PCB Micro
7.        Anti-Tamper PCB Micro
8.        * 

NC Relay for confirmation alarm

9.      

  * NC Relay for confirmation alarm

10.      Spare

Only applicable if enabled

default is disabled

Latching

Timed

Two Button

Unconfirmed

LED Indication

Non EOL

EOL

Non Latching

Untimed

One Button

Confirmed

No Indication

Default Setting in Bold Italic

Version dependant           Plus version only

 * 

Available on plus version only

EOL Settings

*

*

*

*

*

*

Connection for EOL

Connection for EOL

Type A  EOL Selection

Type B  EOL Selection

Type D  EOL Selection

Type E  EOL Selection

6K8/4K7

5K6/5K6

4K7/2K2

1K/1K

LED Indication.

Version Dependant and only applies if LED indication is enabled.

  Green

 

Healthy supply. Non alarm condition.

 

        Steady Red

 

On power up or alarm condition, reset required.

 

    Flashing Red

 

Error condition. Incompatible selection or jumper missing. The unit will  

 

 

 

be non functional until the error is corrected.

 Steady 

Orange

 

Unconfirmed alarm condition.

                Flashing Orange

 

Time delay time needs setting, or set time delay is counting down.

 Flashing Orange/Green

 

Timed mode has set a default following an unnattended power down.

Jumper Selectable Features.

 

Default settings are highlighted in

 Bold

.

It is strongly recommended that the unit is powered down whilst selection is made.

1:- 

Latching

/Non Latching (

Non Latching selection not available on the standard version

).

If latching is selected, the unit will need resetting following activation. This is achieved by pushing and 
holding down the two buttons simultaneously for 5 seconds or more. If non-latching mode is selected, 
the unit will automatically reset 5 seconds after activation.

2:- 

Un-timed

/ Timed (

Time delay selection not available on the standard version

).

Un-timed operation activates immediately on the push of the buttons, this is the normal operation for 
a hold-up device (PA).  If timed operation is selected, on power up the LED flashes orange 
intermittently once per second indicating the delay time needs setting. This is achieved by pushing the 
left button for x number of times of 5 second delay increments, up to a maximumof 24 pushes (this 
gives the maximum of 2 minutes delay). To confirm the time delay and complete the programming, 
press the right button. Following a small delay, confirmation of the set delay time is indicated by the 
LED flashing red the correct number of times the button was pressed. The LED will then turn green 
indicating normal operation. Timed operation is activated by the left hand button, which starts the 
count-down of the set delay time, the count-down will cease immediately on pushing the right hand 
button. If the countdown is not cancelled, on expiration of the set delay time the unit will generate an 
alarm signal either latched or unlatched depending on which option is enabled.  During countdown of 
the delay time the LED will flash orange until the delay time is complete and LED turns red. Even if 
timed mode is selected, the unit will alarm immediately if both buttons are pressed simultaneously. In 
the event of first programming or power failure the unit will wait for a setting sequence as described 
above. If it does not receive an input within 3 minutes, the LED will change from flashing orange and 
will flash between green and orange at one per second, and will only work as a standard 2 button PA, 
for one emergency operation only, the programming mode is unusable and the unit must be powered 
down and the unit re-programmed. This timed mode will ignore what is set in item 3 (Two button or 
one button operation) and item 4 ,(confirmed operation) is not compatible with this timed mode. The  
red LED will flash for wrong selection. 

3:- 

Two

/One button operation (

One button selection not on available on the standard version

).

 

Two button operation requires both buttons to be pressed simultaneously. Not necessarily at exactly 
the same time, as long as both are down at some point. One button operation will allow alarm 
indication if either button is pressed. Item 4 ,(confirmed operation) is non operational in this single 
button mode. The  red LED will flash for wrong selection.

For removal from mounting surface
tamper detection a screw must be
used in this breakout area. 

Tamper spring

For surface mount applications use the low profile back box supplied.
If removal from mounting surface tamper detection is required, there must be a fixing screw in the 
apropriate screw hole as indicated above. Locate the tamper spring over the tapered pillar on 
assembly.
This product can also be fitted flush using a standard UK style pattress box of a depth of 16mm. 
If a deeper box is used please use the extension peg supplied to extend the tamper spring.  
Thread the cable through the centre hole. Keeping excess wire to a minimum, connect the unit 
according to the diagram below.  Take care not to trap any wires when fitting the unit.