43
OVER TEMP
The internal temperature is
higher than normal value
Inverter could be overheated from exposure
to abnormally high ambient temperature or
in combination with direct exposure to the
sun.
Inverter will automatically reconnect to Grid
when
internal
temperature
drops
to
operating range.
EEPROM
FAULT
EEPROM cannot be written
Contact your local service.
6.2 General maintenance
Although the PV-Inverter is designed to be maintenance free, the following regular
inspections would help to ensure the PV Inverter operation at optimal
performance level.
(1) Clean any debris that may settle on heat-sink on the back of the unit.
(2) Inspect Grid connection and PV connection. Re-torque terminal screws.
(3) Check the inverter and cables for any signs of external damage. Contact your
local service immediately if you find any defects.
Do not carry out any repairs on
your own
.
WARNING:
All the installation and wiring connections should be performed only by
qualified technical personnel. Disconnect the inverter from PV modules
and the Power Grid before maintaining and operating the equipment.