CC800A Series

Programmable Charging Scale

CERTIFIED

Calibrated to standards traceable to the

National Institute of Standard and

Technology (NIST).

CC800A

SPECIFICATIONS

Working Load Capacity:

0-220lbs (100kg)

Overload Warning At:

220 lbs (100kg)

Operating Temperature:

14°F to 122°F or -10°C to 50°C

Operating and Storage Humidity:

0 to 95% non-condensing

Display Resolution (oz. / gm. Increments):

.25 ounces (10 grams)

Accuracy:

± 0.05% of reading or ± .25 oz. (10 grams) whichever is greater

Operating Power Source:

Two 9V alkaline battery  (ANSI 1604AC-IEC 6LR61)

Battery Life:

30 hours of continuous use

Battery Indicator:

Battery symbol with 3 segment Power Level Bar Graph

Maximum Working Pressure:

500 PSIG  (34 bar)

Max. Operating Pressure Differential:

485 PSIG

Weight:

8 lbs 8 oz. (3kg 900g)

#73-220-Rev.F_CC800A_Manual  2/2/15  2:13 PM  Page 1

Summary of Contents for PRO-SET CC800A Series

Page 1: ...ng and Storage Humidity 0 to 95 non condensing Display Resolution oz gm Increments 25 ounces 10 grams Accuracy 0 05 of reading or 25 oz 10 grams whichever is greater Operating Power Source Two 9V alkaline battery ANSI 1604AC IEC 6LR61 Battery Life 30 hours of continuous use Battery Indicator Battery symbol with 3 segment Power Level Bar Graph Maximum Working Pressure 500 PSIG 34 bar Max Operating ...

Page 2: ...RE Press and hold for 1 second to tare while the unit is in the WEIGHING mode It returns the display to 00 00 in the SETTING mode The TARE key is not active while the unit is in the HOLD mode In the SET mode the TARE key will reset the programmed amount to zero GO HOLD Initiates the CHARGING or RECOVERY modes per the data entered after pushing the SET key The data entered will determine how long t...

Page 3: ...proceed to either item A or B A When the programmed charge amount is reached the CC800A will sound a continuous beep and the display will show the amount that has been charged sign on the display Set up another charging process by pressing SET RESET twice and follow the instruction in STEP 6 note that the previous setting amount will show B If the refrigerant is no longer being dispensed after 3 m...

Page 4: ...ank to confirm the total weight of the cylinder does not exceed the maximum allowable amount 10 If during the recovery process the gross weight exceeds the programmed maximum tank weight the solenoid valve will close preventing the additional filling of the refrigerant cylinder Exchange the cylinder with an empty one and proceed back to STEP 4 When CHARGE mode has been completed remove the cylinde...

Page 5: ...is active the last weight reading is stored in memory Next time scale is activated scale will resume operation at same point as when Shut Off occured CPS Products Inc 1010 East 31st Street Hialeah Florida 33013 USA Tel 305 687 4121 1 800 277 3808 Fax 305 687 3743 E mail info cpsproducts com Website www cpsproducts com CPS Products Canada LTD 1324 Blundell Road Mississauga Ontario L4Y 1M5 Tel 905 6...

Reviews: