CPS BlackMAX VPC Series Operation Manual Download Page 8

#73-151

Troubleshooting Chart

Condition

Possible Problem

Solution

Unusually noisy

1. Bad bearings.
2. Loose motor bolts.
3. Dirty, low, or improper oil.
4. Air leaks in connections.

1. Replace motor.
2. Tighten bolts.
3. Replace oil.
4. Fix leaks.

High temperature

1. Worn bearings.
2. Low oil level.

1. Replace motor.
2. Add or replace.

Poor vacuum

1. System leaks.
2. Low oil level.
3. Dirty oil.
4. Air leaks at connection.
5. Air leak through seal.
6. Worn rotary mechanism.

1. Fix leaks.
2. Add or replace oil.
3. Flush and replace oil.
4. Fix leaks.
5. Replace shaft seal.
6. Replace cartridge.

Oil leaks

1. Oil leaks through exhaust.
2. Oil leaks through shaft seal.
3. Oil leaks through 

reservoir.

4. System vented pressure.
5. Pump tipped over.

1. Oil level too high.
2. Replace shaft seal.
3. Tighten bolts or replace 

gasket.

4. Check oil level.
5. Check oil level.

Pump does not start

1. No power to motor.
2. Power Switch to ON

1. Check battery

CPS

®

 Products, Inc. guarantees that all products are free of manufacturing and material defects to the original owner 

for one year from the date of purchase. If the equipment should fail during the guarantee period it will be repaired or 

replaced (at our option) at no charge. This guarantee does not apply to equipment that has been altered, misused or 

solely in need of field service maintenance. All repaired equipment will carry an independent 90-day warranty. This repair 

policy does not include equipment that is determined to be beyond economical repair.

Warranty

CPS Products, Inc.

CPS Products, Inc. U.S.A. (Headquarters)

1010 East 31st Street, Hialeah, Florida 33013, USA

Tel: 305-687-4121, 1-800-277-3808, Fax: 305-687-3743

e-mail: [email protected]

website: www.cpsproducts.com

CPS Canada

4605 Crysler Ave. Niagara Falls, Ontario L2E 3V6

Tel: 905-358-3124, Fax: 905-358-7187, 1-866-629-3895,

e-mail: [email protected]

CPS Products N.V

Krijgsbaan 241, 2070 Zwijndrecht, Belgium

Tel: (323) 281 30 40, Fax: (323) 281 65 83, 

www.cpsproducts.be

,

e-mail: [email protected]

CPS Australia PTY. LTD.

109 Welland Avenue, Welland, South Australia 5007

Tel: +61 8 8340 7055, Fax: +61 8 8340 7033

e-mail: [email protected]

www.cpsproducts.com

8

Summary of Contents for BlackMAX VPC Series

Page 1: ...VPC Series 18VDC CORDLESS VACUUM PUMP OPERATION MANUAL ...

Page 2: ...ign allows for operation under high temperature conditions Rated ultimate vacuum of 100 microns Single Stage 15 microns Two Stage All vacuum pumps allow for multiple connections 1 4 SAE for R 22 and other miscellaneous refrigerants applications 5 16 SAE for R410A and R32 applications Accessible oil drain port sight glass make both oil maintenance and accuracy easy To help you get a good start plea...

Page 3: ...tery and battery charger information Do not charge damaged batteries Risk of overheating and fire WARNING Do not operate the vacuum pump on systems under pressure Damage to the pump may occur CAUTION All hoses may contain liquid refriger ant under pressure Contact with refrigerant may cause frostbite or other related injuries Wear proper personal protective equipment such as safety goggles and glo...

Page 4: ...7 lbs w battery Operating Temperature Range 0 C 32 F to 52 C 125 F Power Source 18VDC Li on battery 6 0Ah BL18 series compatible Ultimate Vacuum 100 Microns 15 Microns Oil Capacity 9 oz 250 ml 10 oz 300 ml Construction Heavy Gauge Aluminum Chasis with hard reinforced base and rubber lined steel handle Control System ON OFF power switch Free Air Displacement 2 CFM Intake Fittings 1 4 5 16 SAE 45D M...

Page 5: ...l vacuum pump CPS vacuum pump oil 18VDC Li on 6 0 Ah battery Operational manual Sure Grip Handle Reinforced Base LED Indicator ON OFF Switch Oil Drain Oil Sightglass Inlet Ports 18 Volt DC Li on battery Oil Refill Cap 18 Volt DC Li on battery mount 18 Volt Inlet Solenoid ...

Page 6: ...l cap and add oil until it is seen in the middle of the oil sight glass Re secure cap 3 Remove the 1 4 inlet service port cap turn on the vacuum pump After 15 seconds replace 1 4 cap back on inlet port 4 Re check vacuum pump oil level Add or remove oil if necessary To achieve good final vacuum levels the oil level should be visually seen through sight glass CAUTION DO NOT RUN THIS EQUIPMENT WITH L...

Page 7: ...se the CPS recommended vacuum pump oil VPOQ VPOP VPOG The oil provided with the pump has been specially blended to maintain maximum visosity at normal running temperatures as well as cold weather starts OIL CHANGE PROCEDURES 1 Be sure the pump oil is warmed up if not warm turn vacuum pump ON for 5 minutes 2 Make sure vacuum pump is not plugged in 3 Remove the oil drain cap and drain the contaminat...

Page 8: ...anufacturing and material defects to the original owner for one year from the date of purchase If the equipment should fail during the guarantee period it will be repaired or replaced at our option at no charge This guarantee does not apply to equipment that has been altered misused or solely in need of field service maintenance All repaired equipment will carry an independent 90 day warranty This...

Reviews: