CPS BlackMAX VPC Series Operation Manual Download Page 3

GENERAL INFORMATION

3

General Safety Instructions

ONLY QUALIFIED SERVICE PERSONNEL SHOULD OPERATE THIS UNIT. SOME COUN-

TRIES MAY REQUIRE THE USER TO BE LICENSED. PLEASE CHECK WITH YOUR LOCAL 

GOVERNMENT AGENCY.

CAUTION: THIS EQUIPMENT IS INTENDED FOR USE OF FINAL EVACUATION OF A REFRIG-

ERANT SYSTEM. THE EVACUATION OF MATERIALS ABOVE 5 PSIG MAY CONTAMINATE 

OR DAMAGE THE VACUUM PUMP.

CAUTION: DO NOT RUN THIS EQUIPMENT WITH LOW OR NO OIL. RUNNING THIS EQUIP-

MENT WITH NO LUBRICATION WILL CAUSE PREMATURE 

FAILURE.

DANGER

  -  Avoid  breathing  refrigerant 

vapors and lubricant vapor or mist. Breathing 

high concentration levels may cause heart 

arrhythmia, loss of consciousness, or even 

cause suffocation.

CAUTION

 - Review battery and battery charger 

information. Do not charge damaged batteries. 

Risk of overheating and fire.

WARNING

 - Do not operate the vacuum pump 

on systems under pressure. Damage to the 

pump may occur.

CAUTION 

- All hoses may contain liquid refriger-

ant under pressure. Contact with refrigerant may 

cause frostbite or other related injuries. Wear 

proper personal protective equipment such as 

safety goggles and gloves. When disconnecting 

any hose, please use extreme caution.

CAUTION

 - Avoid breathing refrigerant vapors 

and/lubricant mist. Exposure may irritate eyes, 

nose, throat and skin. Please read the manu

-

facturers Material Safety Data Sheet for further 

safety information on refrigerants and lubricants.

CAUTION

 - Do not use this equipment in the 

vicinity of spilled or open containers of gasoline 

or other flammable substances. Make certain 

that all safety devices are functioning property 

before operating the equipment.

Summary of Contents for BlackMAX VPC Series

Page 1: ...VPC Series 18VDC CORDLESS VACUUM PUMP OPERATION MANUAL ...

Page 2: ...ign allows for operation under high temperature conditions Rated ultimate vacuum of 100 microns Single Stage 15 microns Two Stage All vacuum pumps allow for multiple connections 1 4 SAE for R 22 and other miscellaneous refrigerants applications 5 16 SAE for R410A and R32 applications Accessible oil drain port sight glass make both oil maintenance and accuracy easy To help you get a good start plea...

Page 3: ...tery and battery charger information Do not charge damaged batteries Risk of overheating and fire WARNING Do not operate the vacuum pump on systems under pressure Damage to the pump may occur CAUTION All hoses may contain liquid refriger ant under pressure Contact with refrigerant may cause frostbite or other related injuries Wear proper personal protective equipment such as safety goggles and glo...

Page 4: ...7 lbs w battery Operating Temperature Range 0 C 32 F to 52 C 125 F Power Source 18VDC Li on battery 6 0Ah BL18 series compatible Ultimate Vacuum 100 Microns 15 Microns Oil Capacity 9 oz 250 ml 10 oz 300 ml Construction Heavy Gauge Aluminum Chasis with hard reinforced base and rubber lined steel handle Control System ON OFF power switch Free Air Displacement 2 CFM Intake Fittings 1 4 5 16 SAE 45D M...

Page 5: ...l vacuum pump CPS vacuum pump oil 18VDC Li on 6 0 Ah battery Operational manual Sure Grip Handle Reinforced Base LED Indicator ON OFF Switch Oil Drain Oil Sightglass Inlet Ports 18 Volt DC Li on battery Oil Refill Cap 18 Volt DC Li on battery mount 18 Volt Inlet Solenoid ...

Page 6: ...l cap and add oil until it is seen in the middle of the oil sight glass Re secure cap 3 Remove the 1 4 inlet service port cap turn on the vacuum pump After 15 seconds replace 1 4 cap back on inlet port 4 Re check vacuum pump oil level Add or remove oil if necessary To achieve good final vacuum levels the oil level should be visually seen through sight glass CAUTION DO NOT RUN THIS EQUIPMENT WITH L...

Page 7: ...se the CPS recommended vacuum pump oil VPOQ VPOP VPOG The oil provided with the pump has been specially blended to maintain maximum visosity at normal running temperatures as well as cold weather starts OIL CHANGE PROCEDURES 1 Be sure the pump oil is warmed up if not warm turn vacuum pump ON for 5 minutes 2 Make sure vacuum pump is not plugged in 3 Remove the oil drain cap and drain the contaminat...

Page 8: ...anufacturing and material defects to the original owner for one year from the date of purchase If the equipment should fail during the guarantee period it will be repaired or replaced at our option at no charge This guarantee does not apply to equipment that has been altered misused or solely in need of field service maintenance All repaired equipment will carry an independent 90 day warranty This...

Reviews: