![CPS 28KTL-DO Installation And Operation Manual Download Page 10](http://html.mh-extra.com/html/cps/28ktl-do/28ktl-do_installation-and-operation-manual_2675120010.webp)
7
removed with a wave filter. Then the 3-phase AC voltage is passed through
two-stage relays and EMI wave filter to produce high quality AC power.
PE
Three level
inverter
N
L1
L2
L3
PV1+
PV1+
PV1+
PV1+
PV1-
PV1-
PV1-
PV1-
DC
Switch
MPPT1
MPPT2
PV1+
PV1-
PV2+
PV2-
AC
Output
PV
Input
FUSE Clip
( No FUSE)
PV2+
PV2+
PV2+
PV2+
PV2-
PV2-
PV2-
PV2-
AFD
AC
Switch
Figure 2-2 Schematic diagram of CPS SCA23/28KTL-DO series inverter
2.5 Appearance Description
1
2
3
4
4
5 6 7
8
9
Figure 2-3 Appearance sketch of CPS SCA23/28KTL-DO series inverter