MPA Hub Mount I&O Manual
Table G-3
Cable Connections
Item From
To
Note
1 W1P5 PA1-J5
2 W2P6 PA1-J6
3 W4P5 PA2-J5
4 W3P3 PA2-J6
5 W5P1 S1-J1
6 W6P9 S2-J1
7 W7P10 S3-J3
8 User’s
RS485 A5-J1
9
User’s M&C
A5-J2
Termination connector
must be installed
G.2.3 Coaxial
Cable
Install the coaxial cables WX1 and WX2 between Coaxial Input
Assembly and the amplifier’s input port: output 1 to PA1 and
output 2 to PA2.
G.2.4 Prime
Power
Cable
Check the main section of this manual for proper input voltage
before connection.
G.3.0 System
Operation
G.3.1 General
This section contains instructions for operating the hybrid
combiner subsystem. For operation of the amplifier, see other
sections of this manual. The hybrid combiner is matched at the
input coaxial assembly and at the RF output hybrid. When the
amplifiers are in the transmit mode, output power can be
controlled by varying the subsystem input or by the amplifier’s
Doc. 01031254 Rev. 1