background image

 

 
 
 
LOCATION OF DATA PLATE 

The data plate is located on the side panel. 
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE 
All equipment should be examined for damage before and during unloading. The freight carrier has 
assumed responsibility for its safe transit and delivery. If equipment is received damaged, either 
apparent or concealed, a claim must be made with the delivering carrier. 
 
A) Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then be 
signed by the carrier representative (Driver). If this is not done, the carrier may refuse the claim. The 
carrier can supply the necessary forms. 
 
B) If concealed damage is not apparent until after equipment is uncrated, a request for inspection 
must be made to the carrier within 15 days. The carrier should arrange an inspection. Be certain to 
hold all contents and packaging material. 
 
Installation and service  should be performed by a qualified installer who thoroughly reads, 
understands and follows these instructions. 
 
If you have questions concerning the installation, operation, maintenance or service of this product, 
visit Cooking Performance Group’s website at 

www.CookingPerformanceGroup.com

 
 

SAFETY PRECAUTIONS 

 

DANGER

This  symbol warns of imminent hazard which will result in serious injury or 

death. 

 

WARNING: 

This symbol refers to a potential hazard or unsafe practice, which could result 

in serious injury or death. 

 

CAUTION: 

This symbol refers to a potential hazard or unsafe practice, which could result 

in minor or moderate injury or product or property damage. 

 

NOTICE: 

This symbol refers to information that needs special attention or must be fully 

understood even though not dangerous. 

 

NOTICE: 

This product is intended for commercial use only. Not for household use. 

 

 

  NOTICE: 

Local codes regarding installation vary greatly from one area to another. The 

National Fire Protection Association, Inc., states in its NFPA96 latest edition that local 
codes are “Authority Having Jurisdiction” when it comes to requirement for installation 

 

 

 

of equipment. Therefore, installation should comply with all local codes. 

 
 

Summary of Contents for HP212

Page 1: ...ion can be obtained from your local gas supplier CAUTION These models are designed built and sold for commercial use only If these models are positioned so the general public can use the equipment mak...

Page 2: ...nance you will experience years of reliable operation from this equipment To ensure best results it is important that you read and follow the instructions in this manual carefully TABLE OF CONTENTS IT...

Page 3: ...ughly reads understands and follows these instructions If you have questions concerning the installation operation maintenance or service of this product visit Cooking Performance Group s website at w...

Page 4: ...it THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON COMBUSTIBLE SURFACES ONLY Combustible clearances 6 sides 152 mm 6 rear 152 mm 4 oor 102 mm Noncombustible clearances 0 sides 0 mm 0 rear 0 mm 4 oor...

Page 5: ...he front panel 1 Remove the knobs and front panel 2 Remove the burner from the top of the gas pipe 1 Remove the trivets from the top of the appliance Note Unit Number on side of orifice fittings Plast...

Page 6: ...fficient air supply results in a yellow streaming flame Primary air supply is controlled by an air shutter on the front of the burner 2 Loosen the screws on the front of the burner and adjust the air...

Page 7: ...grabbing the handle and pulling it out of the opening in the front panel To replace the pan reverse this procedure 3 Burner air shutter openings must be kept clean Main burner ports must be kept clea...

Page 8: ...8 EXPLOSION VIEW DRAWING MODEL HP424...

Page 9: ...1 05 1029410 01 05 1029318 01 05 1029365 1 5 Foot HP212 HP424 HP636 01 02 1005373 4 6 Main pipe assy Front HP212 HP424 HP636 06 05 1472181 1 2 3 7 Pilot pipe assy Front HP212 HP424 HP636 06 05 1472180...

Page 10: ...a Website www CookingPerformanceGroup com 12 Orifice HP212 NAT HP424 NAT HP636 NAT 01 20 1068646 2 4 6 HP212 LPG HP424 LPG HP636 LPG 01 20 1068654 2 4 6 13 Dial HP212 HP424 HP636 01 02 1005392 2 4 6 1...

Page 11: ......

Page 12: ...e occurs because of accident carelessness lack of proper set up supervision when required or if the equipment is installed or operated in any manner contrary to the installation and operating instruct...

Reviews: