FLEXIBLE COUPLINGS, CONNECTOR AND CASTERS 

For an appliance equipped with casters, the installation shall be made with a connector that complies 
with  the  Standard  for  Connectors  for  Movable  Gas  Appliances,  ANSI  Z21.69  or  Connectors  for 
Moveable  Gas  Appliances,  CAN/CGA-6.16,  and  a  quick  disconnect  device  that  complies  with  the 
Standard  for  Quick  Disconnect  Devices  for  Use  With  Gas  Fuel,  ANSI  Z21.41,  or  Quick  Disconnect 
Devices for Use With Gas Fuel, CANI-6.9. 

If disconnection of the restraint is necessary, make sure to reconnect restraint after the appliance has 
been returned to its originally installed position. Domestic gas or water connectors are not suitable. 

Restraining device may be attached to the back frame / panel of the unit. 

If the appliance is to be  installed  with casters, a flexible connector  must be used and the same ANSI 
standards  apply.  Locking  front  casters  are  provided  to  limit  the  movement  of  the  appliance  without 
depending on the connector or associated piping. A suitable strain relief must be installed with a flexible 
connector. 

All connections must be sealed with a joint compound suitable for LP gas and all connections must be 
tested with soap water solution before lighting pilots. 

 
INITIAL PILOT LIGHTING 

 

 

CAUTION: 

When lighting pilots and checking for leaks, do not stand with your face 

close to the combustion chamber. 

 

 
All 

COOKING  PERFORMANCE  GROUP

  appliances  are  adjusted  and  tested  before  leaving  the  factory, 

effectively  matching  them  to  sea  level  conditions.  Adjustments  and  calibrations  to  assure  proper 
operation  may  be  necessary  on  installation  to  meet  local  conditions,  low  gas  characteristics;  correct 
possible problems caused by rough handling or vibration during shipment and are to be performed only 
by qualified service personnel. These adjustments are the responsibility of the customer and / or dealer 
and are not covered by our warranty. 
 
Check all gas connections for leaks with a soapy water solution before lighting any pilots. 
 

DO NOT USE ANY FLAME TO CHECK FOR LEAKS 

Before lighting any pilots, make sure that burner valves and thermostats are turned "OFF". 
 

TOP BURNERS / RAISED GRIDDLE / BROILER 

All  top  section  burners  are  equipped  with  constant  burning  pilots.  These  are  to  be  manually  lighted 
immediately after the gas is turned on and the system is checked for leaks. Burner pilots are provided 
for each burner and can be rechecked for proper adjustment. All adjustments can be made with a screw 
driver to the brass pilot valve accessible through the valve cover. 

 
GRIDDLE 

The pilot should be lighted immediately after the gas is turned on and the system is checked for leaks. 
The pilot can be reached with a long match through the valve cover, or by lifting the plate upward and 
accessing  through  the  top.  Adjustment  of  the  pilot  flame  can  be  made  with  a  screwdriver  to  the  pilot 
valve, accessible through the valve cover. 

 

Summary of Contents for 24CPG4BS20

Page 1: ...other flammable vapors or liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Re...

Page 2: ...ocal codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 2 as applicable A manual gas shut off valve must be installed in the gas supply line ahead of the appl...

Page 3: ...ibles The clearances from combustible and non combustible construction of ranges and range mounted salamander broiler or cheese melter are as follows Combustible Non combustible Back 4 0 Sides 10 0 If...

Page 4: ...URE REGULATOR Commercial cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation since service pressures may fluctuate on local demand A pressure...

Page 5: ...e combustion chamber All COOKING PERFORMANCE GROUP appliances are adjusted and tested before leaving the factory effectively matching them to sea level conditions Adjustments and calibrations to assur...

Page 6: ...s 4 through 6 above Turn the oven thermostat knob ON and set to desired temperature setting watch to make sure the oven burner ignites from the pilot and that there are no yellow flames from the burne...

Page 7: ...apy water Re install burner parts in the reverse order GRIDDLES Scrape with a nylon griddle scraper to remove cooked on spills When absolutely necessary use a fine grained stone to scrape Wipe away an...

Page 8: ...echnician once a year for efficient operation of the appliance STAINLESS STEEL All stainless steel body parts should be wiped regularly with hot soapy water during the day and with a liquid cleaner de...

Page 9: ...Page 9 CPG RANGE SERIES 5...

Page 10: ...IFICE HOOD 50 25000 ORIFICE HOOD 53 10000 20 OVEN ORIFICE HOOD 56 15000LP ORIFICE HOOD 57 10000CP 20 OVEN 11 311027 PILOT VALVE 1 8 NPT x 3 16 CC X 90o 31 311026 BURNER STRAIGHT OVEN 12 315727 318220...

Page 11: ...RAISED GRIDLE 41 315419 311924 310472 310467 311826 SHELF 24 RANGE ECONOMY SHELF 36 RANGE ECONOMY SHELF 48 RANGE ECONOMY SHELF 60 RANGE ECONOMY SHELF 72 RANGE ECONOMY 42 310125 310236 310367 311715 3...

Page 12: ...normal labor charges for repair of replacement to the extent that such repair or replacement is performed within 35 miles of the office of an authorized service agency within the continental United S...

Reviews: