RECOMMENDATIONS AND WARNINGS 

 

The  electrical  installation  must  be  performed  by  a  qualified  professional,  in  compliance  with 
the technical and safety regulations in force. This pump is not equipped with a thermal switch, 
so it must be installed under a thermal relay and differential protection in compliance with the 

technical and safety regulations in force. In order to prevent electric shocks in case of damage 
to the electrical wiring, always connect the pump to the system ground. (fig. A) 

 
 
 

 
 

 
 

 

 

ground connection

docking station 

 

>75 cm 

 

 

              copper rod / bar placed in depth

 

    

fig. A 

 

           fixing by welding or screw

Do not connect the pump with damp or wet cables. This pump is not self-priming, so do not run the 
pump empty. If this happens by mistake, immediately disconnect the power  supply, then wait for 
the engine to cool and then fill it with clean water. (fig. B) 

fig. B 

fig. C 

 
 
 
 

 

 
 

Do not cover the motor body with rags or similar, this could cause a fire. Before proceeding with 
the installation, check that the moving parts rotate freely: insert a screwdriver into the recess of the 
motor shaft on the side of the fan protection grid and try to rotate the blades (fig. C). If the 

movement is difficult to strike gently with a hammer the screwdriver in order to unlock the rotation. 
Tampering or modification of the same determine the immediate end of the validity of the 
guarantee and can cause serious damage to the machine and to the user. 

INSTALLATION 

The pump must be installed in a well-ventilated and dry  place, protected from  bad weather 
and exposure to temperatures above 40 ° C. The pump must be installed in compliance with 

the EN 60335-2-41 electrical safety standard: any electrical appliance powered at 230 V must 
be installed at a minimum distance of 3.5 m from the edge of the pool. The base of the pump 
is equipped with holes to be anchored to the ground: fix the pump on a flat and solid surface 

by  adopting  suitable  bolts  for  use  to  avoid  vibrations.  The  pump  must  be  installed  in  a 
horizontal  position  in  order  to  allow  the  correct  operation  of  the  bearings.  The  pipes  for 
transporting water to and from the pump must be fastened without burdening the connection 
points with the pump:  

Summary of Contents for AMBRA

Page 1: ...MANTEINANCE MANUAL Ver 01 2021 06 18 Read carefully AMBRA Circulation water pump...

Page 2: ...p body cover and diffuser made of high quality plastic material Motor shaft in AISI 316 stainless steel Excellent and long lasting mechanical seal Seal support made of glass and polyamide Windings imp...

Page 3: ...2870 17 8 23 16 AMBRA 150M 230 50 6 1 1 5 1 1 2880 20 8 25 18 25 AMBRA 150T 400 50 2 7 3 1 5 1 1 2880 20 8 25 18 AMBRA 200M 230 50 7 1 2 1 5 2880 22 10 28 20 30 AMBRA 200T 400 50 3 1 3 2 1 5 2880 22...

Page 4: ...ith the installation check that the moving parts rotate freely insert a screwdriver into the recess of the motor shaft on the side of the fan protection grid and try to rotate the blades fig C If the...

Page 5: ...the formation of air pockets It is recommended to use a non return valve between the delivery port and the flow control valve in order to avoid dangerous water hammer in the event of a sudden stop of...

Page 6: ...f an accidental dry start immediately disconnect the power supply then wait for the engine to cool and then fill it with clean water Start the pump and check in the three phase version that the direct...

Page 7: ...lso recommended for long periods of inactivity in normal temperature conditions After a long period of inactivity repeat all the operations described for the first start up PROBLEMS AND SOLUTIONS Prob...

Page 8: ...ce of air Check the mechanical joint Transparent perforated plastic cover Clean the clear plastic cover and check the gasket Wrong motor direction Electrical check High absorption Adjust the absorptio...

Reviews: