background image

Instruction  manual  CPL-40  

 

of 

19 

 

 

ELECTRICAL 
PANEL 

SPEED 
CHANGE 

 

 

 

 
 

GRID 
PROTECTION 

BOWL 
LOCKING 
HANDLES 

 
 
 
 
 
 
 
 
 
 
 
 

 

INSTRUCTIONS  FOR USE 

 

 

To be able to work;  the bowl must be mounted  and the bowl protective  grid closed.  Otherwise  it will be 
blocked  by the safety  systems. 
DO NOT REMOVE  OR TAMPER  WITH  THE ELECTRICAL  OR MECHANICAL  GUARDS  OR SAFETY 
DEVICES  ON THE MACHINE.
 

 

The bowl must be in position  BEFORE  the tools.  It must be inserted  with the bowl 

lever down,  putting  the bowl plate,  placed  at the back of the bowl, on the bowl lifting 
arc. 

 

 
 
 
 
 
 

Complete  positioning  by having  the holes  on the bowl support  plates  match  with 
the centering  pins. Block  the bowl with the handles. 

 

 
 
 
 
 

If it was not previously  done,  rotate  the protective  grid of the bowl 
to the open  position  and, after having  chosen  the tool, insert  it 
into the tool holder  shaft.  Once  it is inserted,  turn the tool 
clockwise,  having  the transmission  pin enter the work  position  as 
indicated  in the figure.  Lower  it and insert  the tool lock ring. 

 
 

 

Using  the arrows   é    and ê  , on the control  panel to lift the bowl to the working  position  and close the 
protective  grid of the bowl. At this point,  after inserting  the ingredients,  start the work cycle. 

Summary of Contents for CPL40

Page 1: ...Instruction manual CPL 40 1 of 19 C P srl Via Perotti 5 25125 BRESCIA ITALY USE AND MAINTENANCE INSTRUCTION MANUAL PLANETARY MIXER CPL40 MECHANICAL SPEED VARIATION...

Page 2: ...remain intact and where it can be consulted during the whole life of the machine INDEX SAFETY INSTRUCTIONS 3 RESIDUAL RISKS 3 RESIDUAL RISKS PROHIBITIONS OBLIGATIONS Summarized table 4 SYMBOLS USED AN...

Page 3: ...h a neutral degreasing agent i e with Marseille soap Safety devices The mixer is equipped with some devices which protect its operation as well as the safety of the operator They must not be removed o...

Page 4: ...M8 screws Obligation to carry out earthling ATTENTION Where the required PPE during operations Clean the mixer thoroughly after use Do not remove the safety devices or protective casings Do not introd...

Page 5: ...tood the use and maintenance manual Requesting manual updates Phone customer assistance concerning functioning starting or faults of machinery Requesting spare parts repairs system overhauls intervent...

Page 6: ...k of the bowl on the bowl lifting arc Complete positioning by having the holes on the bowl support plates match with the centering pins Block the bowl with the handles If it was not previously done ro...

Page 7: ...will see 4 blue lines in the center of the lcd display figure 2a Figure 2a figure 2b In event of blue light blinking double check the grid alignment or final bowl position If the light are fixed and y...

Page 8: ...the button MODE you will be able to set seconds too To exit from setting just press again button MODE The time will stop blinking Now you are ready to press start once again and begin the working cyc...

Page 9: ...Potatoes Kg 5 10 15 20 30 butter biter whisk 1 2 Egg white Number of eggs 16 32 50 70 96 Whisk 1 4 Biscuits Number of eggs 15 30 45 60 90 Whisk 1 3 Meringues Sugar Kg 0 75 1 5 2 25 3 4 5 Whisk 1 4 Wh...

Page 10: ...ition of the plate that of the operator respect to the mixer and the AS danger area which must be free from people for a distance A 250 mm TECHNICAL DATA PACKAGING DIMENSIONS AND WEIGHT There are four...

Page 11: ...possible and make sure they come out from the pallet Work in an area free from persons and animals During movement always keep the load as close to the ground as possible Use the required P P E STORA...

Page 12: ...odifications or repairs carried out by the customer or third parties in an incompliant fashion or without the prior consent of the supplier The following conditions constitute improper use of the mixe...

Page 13: ...of the mixer downstream the differential protection board Stop circuit and safety micro switch of grid Purpose to stop the mixer immediately and unconditionally Function pressing the STOP button or li...

Page 14: ...s not jet proof Do not wash it with running water Clean it with a moist cloth and neutral detergents such as degreasing agents based on Castile soap To carry out interventions not specially mentioned...

Page 15: ...f construction Position description item code and desired amount of pieces requested Send the request to C P SRL via Perotti 5 25125 Brescia BS Italy MAIN COMPONENTS Raw materials used almost all of t...

Page 16: ...S LIST this is a brand new generation of C P SRL planetary mixers the following chart can be little bit different from the machine you have In case contact the factory to get the updated one We will s...

Page 17: ...Bowl lifting plate CPL 40 11 4 095052 1 Plate distance pad 12 1 MARKET Motor Gr 90 B14 for CPL 40 13 1 095036 2 Cogwheel Z15 14 1 095008 9 Motor seat CPL 40 CPL 60 15 1 095208 1 Top casing CPL 40 16 1...

Page 18: ...1 Check connection Pressing the START button the mixer does not start 1 The slide is not in position or the front grid is not closed 2 Safety micro switch anomalies 1 Lift the slide and reposition it...

Page 19: ...from other waste Differentiated waste collection of this appliance having reached the end of its life is organised and managed by the manufacturer The user who desires to dispose of the present applia...

Reviews: