19
can't test signal from foot
rest recline actuator
1.foot rest recline actuator
is broken
2.foot rest actuator motor
wire is disconnected
3.the signal wire of foot
rest actuator is
disconnected.
1.change foot rest recline
actuator
2.check whether the foot
rest recline actuator motor
wire is well connected.
3.check whether the signal
wire of foot rest actuator is
well connected
activate
auto-check
model
25
when start the backrest
recline actuator, there is
no counting signal for
more than 2.5 seconds
1.backrest recline
actuator is broken
2.backrest recline
actuator wire is
disconnected
3.the signal wire of the
backrest recline wire is
disconnected
1.change backrest recline
actuator
2.check whether the
backrest recline actuator
motor wire is well
connected.
3.check whether the signal
wire of the backrest recline
actuator is well connected
activate
auto-check
model
26
when start the zero-gravity
actuator, there is no
counting signal for more
than 2.5 seconds
1.Zero-gravity actuator is
broken
2.zero-gravity actuator
wire is disconnected.
3.the signal wire of
zero-gravity actuator is
disconnected
1.change zero-gravity
actuator
2.check whether the
zero-gravity motor wire is
well connected.
3.check whether the signal
wire of zero-gravity
actuator is well connected
activate
auto-check
model