
4
3. CUSTOM HOOD PREPARATION
WARNING
!
When building a custom hood, always follow all applicable construction codes and standards.
The custom hood must be constructed to fit the size and shape of the power pack. See chart and illustration below for details.
S
IZE
T
OTAL
WEIGHT
P
OWER
PACK
WIDTH
(A)*
36”
66
LB
.
34 7/16”
42”
73
LB
.
40 7/16”
48”
80
LB
.
46 7/16”
12
6 3/4
5 1/4
A
6 1/4
13 1/4
6 3/16
6 1/2
≈
28 3/8
11 1/16
HD1072
C
L
*Includes rivet heads.
Since the power pack mounting holes are located on the front and rear sides, plan to install a wood frame in the front and sides to support
the power pack using the screws provided in the parts bag.
For an aesthetic gap around the power pack,
measure the actual width of the power pack and add 1/16”.
A + 1/16
HD1073
28 7/16"
HH0271
WARNING
!
The custom wood hood must be positively secured to wall studs or other wooden framework behind the wall.
Make sure it is capable of supporting its own weight and the weight of the power pack. Failure to do so may cause
personal injury or damage to surfaces below.
D
IMENSIONS
IN
INCHES