Never attach an unregulated gas line to the appliance. 

Connection to an unregulated gas line can cause 

excessive heat or fire and the risk of property damage, 

bodily injury, or death.

 

IMPORTANT:

 

Before connecting side burner to gas source, make sure side burner control knobs are in the 

“OFF” position.

 

 

Verify the type of gas supply to be used, either natural or liquid propane, and make sure the marking on 
the appliance rating label agrees with that of the gas supply.    Do not connect a Coyote liquid propane 
gas side burner to a natural gas supply, and do not connect a Coyote natural gas side burner to a liquid 
propane gas supply.   

 

All pipe sealants must be an approved type and resistant to the actions of LP gas. Never use pipe sealant 
on flare fittings. 

 

The installation of this appliance must conform with local codes or, in the absence of local codes, with 
either National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Natural Gas and Propane Installation Code, CSA 
B149.1, or Propane Storage and Handling Code, B149.2, or the Standard for Recreational Vehicles, ANSI 
A 119.2/ NFPA 1192M, and CSA Z240 RV Series, Recreational Vehicle Code, as applicable.                   

Gas valves are preset at the factory to operate on liquid propane or 
natural gas. If you wish to convert, be sure to contact your side 
burner dealer FIRST! 

 

 

Always check the rating plate to make sure gas supply to which you connect the side burner is the gas type for 
which the side burner is manufactured.    A Coyote liquid propane (LP) gas side burner is designed to operate on 
propane gas ONLY, at a pressure regulated at 11” (279.4mm) water column (W.C.) when equipped with the 
correct propane orifices on the valves and a propane regulator on the supply line regulated at the residential 
meter. A Coyote liquid propane gas side burner comes with a propane regulator that is designed to be used with 
a standard 20 lb. gas cylinder and those cylinders must be constructed and marked in accordance with 
specifications of the US Department of Transportation for propane gas cylinders.   

 

 

  Liquid propane (LP) gas is flammable and hazardous if handled improperly. Know its characteristics 

before using any propane products. 

NOTE: Coyote strongly recommends that a qualified service technician perform 
the initial installation and all conversions or modifications to the gas supply. 

Liquid Propane Gas Supply

 

Gas Requirements

 

Summary of Contents for C1CSB-2LP

Page 1: ...bling grill Leave this manual with grill for future reference To consumer Keep this manual for future reference as it contains important Warnings and Instructions COYOTE OUTDOOR LIVING INC Coyote Stai...

Page 2: ...y your new side burner and thank you for choosing our product We hope you consider us for future purchases Read and save the instructions Obey all Warnings and Instructions This Manual provides specif...

Page 3: ...l not be stored in the vicinity of this or any other appliance DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury CAUTION CAUTION ind...

Page 4: ...specified clearances listed in this Manual on page 9 7 NEVER leave the side burner unattended while cooking 8 Risk of Explosion NEVER use natural gas in a unit designed for liquid propane gas or vice...

Page 5: ...o the rack located just under the side burner 25 Fire Hazard Grease is extremely flammable Let hot grease cool down before attempting to handle or dispose of it After use and cool down the drip tray s...

Page 6: ...rust or burn through 5 years limited Flavorizer Bars no rust or burn through 2 years limited Ignition systems Valves 1 year limited Stainless steel frame housing Limited Lifetime Coyote Outdoor Living...

Page 7: ...ice or damages caused by flashback fire or grease fire This limited warranty does not cover scratches dents corrosion or discoloration caused by weather heat abrasive and chemical cleaners pool or spa...

Page 8: ...the side burner in a building garage breezeway shed or other such enclosed areas without an approved ventilation system When in use the side burner will generate a lot of smoke When installing your s...

Page 9: ...M and CSA Z240 RV Series Recreational Vehicle Code as applicable Gas valves are preset at the factory to operate on liquid propane or natural gas If you wish to convert be sure to contact your side bu...

Page 10: ...seal has been obtained The cylinder must be arranged for vapor withdrawal It must also include a collar to protect the cylinder valve A safety relief device having direct communication with the vapor...

Page 11: ...or safety relief valve You may damage the valve and cause a leak Leaking propane may result in explosion fire severe personal injury or death 2 If a leak is detected at any time or you cannot stop a...

Page 12: ...kwise LP Tank Removal Transport and Storage Turn OFF all control knobs and LP tank valve Turn coupling nut counterclockwise by hand only do not use tools to disconnect Install safety cap onto LP tank...

Page 13: ...y company However it is the responsibility of the owner installer to verify that the correct regulator is purchased for the intended application and that it is installed properly o As codes vary from...

Page 14: ...result in a low flame or a hazardous condition that could result in a fire or explosion Natural Gas Supply and Connection 1 Make sure all burner valves are in the OFF position 2 All NG units need to...

Page 15: ...e grill when lighting ALWAYS inspect the hose before using the grill If there is excessive abrasion or wear or if the hose is cut it must be replaced prior to the outdoor cooking gas appliance being p...

Page 16: ...then to your valve and finally into the burner where it will meet the spark from the igniter at the front of the burner Conversely if you turn the knob too slowly you can cause a build up of gas in t...

Page 17: ...utensils used to handle raw food before using them to handle cooked food Always wash all vegetables seafood and poultry before cooking Always leave uncooked foods in the refrigerator until you are rea...

Page 18: ...cleaned periodically to prevent buildup of debris NOTE Allow the drip tray to cool before attempting to clean IMPORTANT Do not leave the side burner outside during inclement weather unless it is cove...

Page 19: ...ner to cool before cleaning polishing stainless steel Do not clean or polish your side burner s stainless steel when the gill is in operation or still hot 2 To clean the stainless steel wash off all d...

Page 20: ...tub 4 Do not store pool chemicals in your island or island cabinets How to Remove Scratches from your Stainless Steel If your situation is a little more serious and you have obtained scratches in your...

Page 21: ...d other flammable vapors and liquids 2 Do not obstruct the flow of combustion and ventilation air 3 Keep the ventilation opening s of the cylinder enclosure free and clear from debris 4 Visually check...

Page 22: ...ts contact our Coyote Customer Service line at 855 520 1559 Problem Possible Causes and Solutions Burner will not light when the igniter button is turned Is your gas supply turned on If this is an L P...

Page 23: ...lve is open and cylinder has fuel Low heat with the knob on HIGH Check to see if the fuel hose is bent or kinked Make sure the cooking area is clear of dust Check your gas supply and gas pressure If i...

Page 24: ...Knob base 1 CICSB12 3 Burner 1 CICSB03 13 knob 1 CICSB13 4 Electrode 1 CICSB04 14 Control Panel 1 CICSB14 5 Burner box CICSB05 15 Logo Badge 1 CICSB15 6 Gas hose 1 CICSB06 16 LP Regulator 1 CICSB16 7...