background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                                   

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

9. Key Features 

 

36PCS CREE XLamp XP-E 3W LEDs (R,G,B,W) 

50,000 hours life span for LEDs and low power consumption 

Intelligent temperature sensor for LEDs(over heat protection) 

High efficiency 6 degree optic lens 

Color range with 16.7 millions additive RGBW colors 

High light output as 1220LUX@ 7M at full 

0-100% smooth linear dimmer with flicker free 

20t/s strobe effect with variable speed   

Pre-programmed random strobe and pulse effects 

15CH modes switchable from operation menu 

Built-in programs with macro effects 

DMX512, master-slave and sound activated controllable or auto operation 

Green LCD display 

Quiet, smooth and fast PAN/TILT movement 

Low noise and efficient FAN cooling system 

540° PAN and 270° TILT movement 

Scan position memory, auto reposition after unexpected movement 

Compact size with only 4.9KG body and 310mm in height 

IEC power connector 

45

 max ambient temperature 

IP20 protection rating 

3-Pin XLR DMX input/output 

 
 
 
 

2. Safety Instructions 

 

 

 

This device has left the factory in perfect condition. In order to maintain this condition and to ensure a 

safe operation, it is absolutely necessary for the user to follow the safety instructions and warning 

notes written in this user manual. 

 

If the device has been exposed to temperature changes due to environmental changes, do not switch 

it on immediately. The arising condensation could damage the device. Leave the device switched off 

until it has reached room temperature. 

This device falls under protection-class I. Therefore it is essential that the device be earthed. 

The electric connection must carry out by qualified person. 

The device shall only be used with rate voltage and frequency. 

Make sure that the available voltage is not higher than stated at the end of this manual. 

Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case, 

replacement of the cable must be done by an authorized dealer. 

Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the 

power cord by the plug. Never pull out the plug by tugging the power cord. 

During initial start-up some smoke or smell may arise. This is a normal process and does not 

necessarily mean that the device is defective, it should decrease gradually. 

Please don't project the beam onto combustible substances. 

Fixtures cannot be installed on combustible substances, keep more than 50cm distance with wall for 

smooth air flow, so there should be no shelter for fans and ventilation for heat radiation. 

If the external flexible cable or cord of this luminaire is damaged, it shall be  exclusively replaced by the 

manufacturer or his service agent or a similar qualified person in order to avoid a hazard. 

 

 

 

Summary of Contents for LEDBEAM 3603

Page 1: ...LEDBEAM 3603 User Manual KEEP THIS MANUAL FOR FUTURE NEEDS ...

Page 2: ...nsumption 108W Dimensions 152 D 265 W 310 H mm Packing Dimensions 260 D 320 W 335 H mm Net Weight 4 9kg Gross Weight 7kg 11 Maintenance and Cleaning The following points have to be considered during the inspection 1 All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded 2 There must not be any deformations on the housing color lenses fixa...

Page 3: ...e changes due to environmental changes do not switch it on immediately The arising condensation could damage the device Leave the device switched off until it has reached room temperature This device falls under protection class I Therefore it is essential that the device be earthed The electric connection must carry out by qualified person The device shall only be used with rate voltage and frequ...

Page 4: ...rly when installing the fixture Make sure the lens are in good condition It s recommended to replace the units if there are any damages or severe scratch Make sure the fixture is operated by qualified personnel who knows the fixture before using Keep the original packages if any second shipment is needed Don t try to change the fixtures without any instruction by the manufacturer or the appointed ...

Page 5: ...he fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet Clamp Mounting T he LEDBEAM 363 provides a unique mounting bracket assembly that integrates the bottom of the base the included Omega Br...

Page 6: ...ram below DMX 512 connection with DMX terminator For installations where the DMX cable has to run a long distance or is in an electrically noisy environment such as in a discotheque it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 Ω resistor connected between pins 2 an...