CountyLine CLSS5 Owner'S Manual Download Page 2

Safety 2

Important Safety Instructions

SAVE THESE INSTRUCTIONS - This manual contains 
important instructions that should be followed during 
installation, operation, and maintenance of the product. 

 This is the safety alert symbol. When you see this 

symbol on your pump or in this manual, look for one of 
the following signal words and be alert to the potential 
for personal injury!

 indicates a hazard which, if not avoided, will 

result in death or serious injury.

 indicates a hazard which, if not avoided, 

could result in death or serious injury.

 indicates a hazard which, if not avoided, 

could result in minor or moderate injury.
NOTICE addresses practices not related to 
personal injury.
Carefully read and follow all safety instructions in this 
manual and on pump .
Keep safety labels in good condition. Replace missing or 
damaged safety labels.
California Proposition 65 Warning

 This product and related accessories contain 

chemicals known to the State of California to cause 
cancer, birth defects or other reproductive harm.
1.  To avoid risk of serious bodily injury and property 

damage, read the safety instructions carefully before 
installing this pump.

2.  Follow local and/or national plumbing and electrical 

codes when installing the pump.

3. 

 Risk of fire and explosion . Can cause 

severe injury, property damage or death. To avoid 
risk of fire and explosion, Pump water only with this 
pump. Do not use this pump in an atmosphere that 
might contain flammable fumes or vapors.

4. 

 Risk of burns . If water is trapped in the 

pump during operation it may turn to steam. Trapped 
steam can lead to explosion and burns. Never run 
the pump with the outlet closed or obstructed.

5. 

 Risk of explosion . Do not ground to 

a gas supply line. The pump body may explode if 
used as a booster pump unless a relief valve capable 
of passing the full pump flow at 60 PSI (414 kPa) 
is installed. Never run the pump dry. To do so can 
damage internal parts, overheat pump (which can 
cause burns to people handling or servicing pump), 
and will void warranty!

6. 

 Risk of burns . Motors are designed to 

operate at high temperatures. To avoid burns when 
servicing pump, allow it to cool for 20 minutes after 
shut-down before handling.

7.  If used with a well for potable water, always 

disinfect the well and test the water for purity before 
using. Check with your local health department for 
testing procedures.

8.  Complete pump and piping must be protected 

against freezing. Freezing will cause damage and 
void the warranty.

9.  This pump is not designed, nor intended, for the 

pumping of chemicals or corrosive liquids. Pump 
water only with this pump.

10. Do not run pump dry. If the pump is dry, damage 

will result and void the warranty.

11. 

 Risk of electric shock . Can shock, burn 

or kill.

•  The pump is supplied with a 3-conductor grounding 

type cord. Connect only to a properly grounded, 
GFCI protected outlet. Do not lift the pump by the 
electrical cord.

 

Match the motor voltage and the power supply 
voltage. The supply voltage must be /- 10% 
of the motor nameplate voltage. Incorrect voltage 
can cause fire or seriously damage the motor 
and will void the warranty. If in doubt, consult a 
licensed electrician.

•  The pump is non-submersible. Keep the motor dry at 

all times. Do not wash the motor. Do not immerse. 
Protect the motor from wet weather.

•  If using an extension cord, use only a UL approved 

indoor/outdoor, 3-wire, grounding type cord. Do not 
allow any part of the cord or the receptacle ends to 
sit in water or in damp locations.

•  Unplug the pump before servicing. To avoid 

fatal shocks, proceed as follows if the pump 
needs servicing.
A.  Disconnect the power  to the pump outlet box 

before pulling the pump plug.

B.  Take extreme care when changing fuses. To 

reduce the chance of fatal electrical shocks, DO 
NOT stand in water or put your finger in the 
fuse socket.

C.  Ground the pressure switch or motor before 

before running this pump.

D.  Plug pump into a Ground Fault Circuit 

Interrupter (GFCI) protected grounded 
outlet only.

Summary of Contents for CLSS5

Page 1: ...Parts For further operating installation or maintenance assistance Call 800 535 4950 English Pages 2 8 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o manteni...

Page 2: ...y To do so can damage internal parts overheat pump which can cause burns to people handling or servicing pump and will void warranty 6 Risk of burns Motors are designed to operate at high temperatures...

Page 3: ...l rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed car...

Page 4: ...pe so that the pump body does not take the weight of piping or fittings Boosting City Water Pressure Risk of explosion and scalding Never run the pump against a closed discharge To do so can boil the...

Page 5: ...mp Risk of burns Never run pump dry Running the pump without water may cause the pump to overheat damaging the seal and possibly causing burns to persons handling the pump Fill the pump with water bef...

Page 6: ...plugs Refill the pump and piping You may have to repeat this several times in order to get all of the trapped air out of the piping A pump lifting water 25 may take as long as 15 minutes to prime Cong...

Page 7: ...dy in use has lost prime through 1 Air leaks 1 Check all connections on suction line and shaft seal with shaving cream 2 Water level below suction pipe inlet 2 Lower suction line into water and re pri...

Page 8: ...9 Intermediate Support 1 721S4460 10 Handle with Handle Grip 1 751S8960 11 Washer Handle 1 121P1500 12 Screw Handle 1 121P1600 13 Lock Nut Handle 1 121P0020 14 Water Singer 1 102P0540 15 Fan Cooling 1...

Page 9: ...las personas que est n manipulando o reparando la bomba y anular la garant a 6 Riesgos de quemaduras Los motores han sido dise ados para funcionar a alta temperatura Para evitar quemaduras cuando se...

Page 10: ...merciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de CountyLine Las bombas cloac...

Page 11: ...tuber as de manera que la unidad de la bomba no deba soportar el peso de las tuber as o de los accesorios Re fuerzo de la presi n de las aguas p blicas Riesgo de exposion y quemaduras Nunca haga march...

Page 12: ...nexi n a tierra en una l nea de suministro de gas Nunca haga marchar una bomba hacia una descarga cerrada ya que eso puede hacer hervir el agua dentro de la bomba produciendo una presi n peligrosa en...

Page 13: ...ado Vuelva a llenar la bomba y la tuber a Es posible que deba repetir esto varias veces para sacar todo el aire atrapado en la tuber a La cebadura de una bomba que levanta agua a 25 pies puede demorar...

Page 14: ...e 1 Verifique todas las conexiones en la l nea de aspiraci n y el sello del eje con agua jabonosa 2 Nivel del agua debajo de la admisi n de la tuber a de aspiraci n 2 Baje la l nea de aspiraci n dentr...

Page 15: ...1S8960 11 Rondelle de la poign e 1 121P1500 12 Vis de la poign e 1 121P1600 13 crou de la poign e 1 121P0020 14 D flecteur d eau 1 102P0540 15 Ventilateur de refroidissement 1 102P0570 16 Carter du ve...

Page 16: ......

Reviews: