background image

Safety 2

Important Safety Instructions

SAVE THESE INSTRUCTIONS - This manual contains 
important instructions that should be followed during 
installation, operation, and maintenance of the product. 
Save this manual for future reference.

 This is the safety alert symbol. When you see this 

symbol on your pump or in this manual, look for one of 
the following signal words and be alert to the potential 
for personal injury!

 indicates a hazard which, if not avoided, will 

result in death or serious injury.

 indicates a hazard which, if not avoided, 

could result in death or serious injury.

 indicates a hazard which, if not avoided, 

could result in minor or moderate injury.
NOTICE addresses practices not related to 
personal injury.
Carefully read and follow all safety instructions in 
this manual and on pump. 
Keep safety labels in good 
condition. Replace missing or damaged safety labels.

General Safety

1.  To avoid risk of serious bodily injury and property 

damage, read safety instructions carefully before 
installing pump.

2.  Follow local and/or national plumbing and electrical 

codes when installing pump.

3. 

 Risk of electric shock. Can shock, burn 

or kill. Proceed as follows if pump needs servicing:
A.  Disconnect power to pump outlet box before 

pulling pump cord plug. After plug is pulled, let 
pump cool for 20 minutes before attempting to 
work on it.

B.  Take extreme care when changing fuses. To 

reduce chance of fatal electrical shocks, DO 
NOT stand in water or put your finger in the 
fuse socket.

C.  Ground electrical outlet box.
D.  Use only Ground Fault Circuit Interrupter (GFCI) 

protected grounded outlet for cord plug.

4.  

 Risk of burns. Never run pump dry. To 

do so can damage internal parts, overheat pump 
(which can cause burns to people handling or 
servicing pump), and will void warranty!

5. 

 Risk of fire and explosion. Can cause 

severe injury, property damage or death. Do not 
pump gasoline or any other flammable liquids with 
pump. Do not use pump in atmosphere that might 
contain flammable fumes or vapors.

6.  Do not pump chemicals or corrosive liquids with 

pump. Pump clean water only with this pump.

7. 

 Risk of explosion and scalding. If water 

is trapped in pump during operation, it may turn to 
steam, leading to explosion and burns. Never run 
pump with outlet shut off or blocked.

8.  To avoid clogging pump and damage to shaft 

seal, do not pump water containing solids, foreign 
material, sand, silt, or abrasives. Always have 
suction strainer installed when pump is operating. 
Failure to use strainer may cause pump failure and 
void warranty.

9.  Clean strainer and flush out pump after each use.
10. Make sure all hose and pipe connections in suction 

line are tight. An air leak in suction line will prevent 
priming and reduce performance.

11. Tighten all piping to pump hand tight +1-1/2 turns 

only. Overtightening may break pump and will 
void warranty.

       

 WARNING

Hazardous pressure!  

Install pressure relief  

valve in discharge pipe.
Release all pressure on  

system before working on  

any component.

 WARNING

Hazardous voltage.  

Can shock, burn, or cause 

death.
Ground pump before  

connecting to power  

supply. Disconnect power 

before working on pump, 

motor or tank.

 Wire motor for correct 

voltage. See “Electrical” 

section of this manual 
and motor nameplate.

 Ground motor before 
connecting to power 
supply.
 Meet National Electrical 
Code, Canadian 
Electrical Code, and 
local codes for all 
wiring.
 Follow  wiring 
instructions in this 
manual when 
connecting motor to 
power lines.

Sealing Pipe Joints

Use only PTFE pipe thread sealant tape or PTFE-based 
joint compounds for making all threaded connections 
to the pump itself. Do not use pipe joint compounds 
on plastic pumps: they can react with the plastic in 
pump components. Make sure that all pipe joints in 
the suction pipe are air tight as well as water tight. If 
the suction pipe can suck air, the pump will not be 
able to pull water from the well. 

Summary of Contents for CLBU10C

Page 1: ...For further operating installation or maintenance assistance Call 1 800 535 4950 English Pages 2 9 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimien...

Page 2: ...y property damage or death Do not pump gasoline or any other flammable liquids with pump Do not use pump in atmosphere that might contain flammable fumes or vapors 6 Do not pump chemicals or corrosive...

Page 3: ...n commercial rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been...

Page 4: ...igure 1 Plastic pipe can be used for all installations Electrical Risk of electric shock Can shock burn or kill Unplug pump before servicing it Do not handle pump or attempt to work on pump with wet h...

Page 5: ...outlet and remove all piping or hoses from the pump 2 To avoid breaking the brushes when you remove or replace the motor shaft remove the motor brushes see Brush Changing Procedure Put the brushes wh...

Page 6: ...wires on the motor side of the crimps as close to the connectors as possible in other words leave yourself as much wire in the motor as possible 4 Strip all the wires back about 5 8 from the wire ends...

Page 7: ...0407 Step 1 IN IN OUT OUT 5604 0407 IN IN OUT OUT A B IN OUT IN OUT IN OUT IN OUT Step 2 IN IN OUT OUT 5604 0407 IN IN OUT OUT IN OUT IN OUT IN OUT IN OUT A B Step 6 5605 0407 IN OUT Step 3 5606 0407...

Page 8: ...nd or pressure Air pockets or leaks in suction line Check suction piping Clogged impeller Remove and clean Pump loses prime Air leaks in suction line Check suction piping Excessive suction lift and op...

Page 9: ...Shaft Seal 1 4C Square Cut O Ring 1 5 Seal Plate 1 6 Handle With Hardware 1 C54 30 7 Power Cord 1 PS17 1507 8 Brush Kit Includes 1 Pair of Brushes with springs and Retainer Caps 1 FPPKG 226 P2 9 Motor...

Page 10: ...ar lesiones graves da os materiales o muerte No bombee gasolina ni ning n otro l quido inflamable No use la bomba en una atm sfera que pueda contener humos o vapores inflamables 6 No bombee productos...

Page 11: ...ados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de Coun...

Page 12: ...muerte Desenchufe la bomba antes de efectuar el servicio de la misma No toque la bomba ni intente trabajar en la misma con las manos mojadas o estando parado sobre un suelo mojado Enchufe la bomba so...

Page 13: ...cuando saque o cambie el eje del motor saque las escobillas del motor consulte el Procedimiento para cambiar las escobillas Coloque las escobillas en donde no se puedan perder o da ar mientras usted c...

Page 14: ...o del motor de los pliegues tan cerca de los conectores como sea posible es decir deje todo el cable que pueda en el motor 4 Pele todos los cables hasta unos 5 8 del extremo de los mismos AVISO Haga l...

Page 15: ...s 15 5602 0407 Paso 1 IN IN OUT OUT 5604 0407 IN IN OUT OUT A B IN OUT IN OUT IN OUT IN OUT Paso 2 IN IN OUT OUT 5604 0407 IN IN OUT OUT IN OUT IN OUT IN OUT IN OUT A B Paso 6 5605 0407 IN OUT Paso 3...

Page 16: ...olsillos de aire o p rdidas en la tuber a de aspiraci n Revisar la tuber a de aspiraci n Impulsor obstruido Sacar y limpiar La bomba se desceba P rdida de aire en la tuber a de aspiraci n Revisar la t...

Page 17: ...ios de ferreter a 1 C54 30 7 Cord n el ctrico 1 PS17 1507 8 Juego de escobillas Incluye 1 par de escobillas con resortes y casquetes de retenci n 1 FPPKG 226 P2 9 Motor 1 Si la Unidad de la bomba o el...

Page 18: ......

Page 19: ......

Page 20: ......