Safety 2

Important Safety 

Instructions

SAVE THESE INSTRUCTIONS - This manual 

contains important instructions that should be 

followed during installation, operation, and 

maintenance of the product.

This is the 

safety alert symbol. When you see this symbol 

on your pump or in this manual, look for one of 

the following signal words and be alert to the 

potential for personal injury!

indicates a hazard which, if not 

avoided, will result in death or serious injury.

indicates a hazard which, if not 

avoided, could result in death or serious injury.

indicates a hazard which, if not 

avoided, could result in minor or moderate injury.
NOTICE addresses practices not related to 

personal injury.
Carefully read and follow all safety instructions 

in this manual and on pump .
Keep safety labels in good condition. Replace 

missing or damaged safety labels.
California Proposition 65 Warning

This product and related 

accessories contain chemicals known to the 

State of California to cause cancer, birth defects 

or other reproductive harm.

1.  Read this manual carefully. Failure to follow 

these Instructions could cause serious bodily 

injury and/or property damage.

2.  Consult installer or licensed plumber for 

correct relief valve. Install system according to 

local codes.

3.  Always test water from well for purity before 

using. Check local health department for 

testing procedure.

4.  Before installing or servicing tank, BE SURE 

pump electric power source is disconnected. 

Release all water pressure before working on 

tank or system. Release air pressure before 

removing cover flange.

5.  Install relief valve in pump supply line to tank, 

as close to tank as possible.

6.  BE SURE pump electrical circuit is 

properly grounded.

7.  Remove bleeder orifices, air volume controls 

or other air charging devices in existing system.

8.  DO NOT USE tank as a surge suppressor.

Risk of explosion . To prevent 

possible serious or fatal injury and/or damage to 

equipment, system pressure must be less than 

100 pounds per square inch (PSI) (689kPa) under 

any circumstances. Failure to follow instruction 

can result in tank blowup. If system discharge 

pressure can exceed 100 PSI (689kPa), install a 

relief valve capable of passing the full pump 

volume at 100 PSI (689kPa).

Risk of freezing . Do not allow 

pump, tank, or piping system to freeze. Freezing 

can severely damage equipment and may lead 

to tank explosion and serious injury. Allowing 

tank to freeze voids tank warranty.

Summary of Contents for 312419699

Page 1: ...maintenance assistance Call 800 535 4950 English Pages 2 7 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 800 535 4950 Español Páginas 8 13 293 Wright Street Delavan WI 53115 Phone 800 535 4950 Fax 800 526 3757 www tractorsupply com CLPT20H CLPT20 CLPT36 CLPT52 CLPT85 CLPT119 4108 1101 ASB PROS 2878 1013 ...

Page 2: ...bodily injury and or property damage 2 Consult installer or licensed plumber for correct relief valve Install system according to local codes 3 Always test water from well for purity before using Check local health department for testing procedure 4 Before installing or servicing tank BE SURE pump electric power source is disconnected Release all water pressure before working on tank or system Rel...

Page 3: ...l rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the re...

Page 4: ...rent than drawdown Tank capacity is the actual physical volume of the sheet metal that makes up the tank Operating Cycle 1 Tank nearly empty air expands filling area above bladder Figure 2A 2 Water enters tank air is compressed above bladder as it fills with water Figure 2B 3 Pump up cycle completed air compressed to OFF setting of pressure switch Figure 2C 4 Water drawn from tank compressed tank ...

Page 5: ...according to Chart 1 Flush all air out of piping system and water reservoir portion of pre charged tank Adjustment of tank pre charge is required on new installations pumps requiring re priming and pumps disassembled for service Adjust tank precharge as follows 1 Open faucets furthest from tank and run pump 2 Run pump until sputtering stops and steady stream of water flows 3 Open and close faucets...

Page 6: ...tanks have separate inlet and outlet ports Pre charge tanks have one port serving both functions When replacing standard tank with a pre charge tank run pipe from pump into a tee as shown Second leg of tee goes to tank elbow Third leg goes to existing service Product Information Pre ChargedTanks Model Drawdown Gals L 20 40 PSI 138 276kPa 30 50 PSI 207 345kPa 40 60 PSI 276 414kPa CLPT20 6 9 26 1 5 ...

Page 7: ...ith Cap 1 U212 160 3 Water Cell Vinyl 1 U20 13 U20 9 U20 10 U20 14 U20 20 4 Cover Flange 1 U31 446P U31 447P U231 462P 5 Flanged Nut 5 16 18 Hex 6 U36 202BT 6 Base 1 U31 505P U31 512P Pump Mounting Bracket 1 TNKBR P2 Not illustrated sold separately Ref Description Qty CLPT20H 1 Air Valve Cover 1 U31 380P 2 Air Valve with Cap 1 U212 160 3 Water Cell Vinyl 1 U20 13 4 Cover Flange 1 U31 446P 5 Flange...

Page 8: ...a de la válvula de alivio correcta Instale el sistema de conformidad con los códigos locales 3 Siempre verifique la pureza del agua del pozo antes de utilizarla Consulte con el departamento de salud local sobre los procedimientos de prueba 4 Antes de instalar o prestar servicios al tanque ASEGÚRESE DE QUE la corriente eléctrica a la bomba haya sido desconectada Reduzca toda la presión de agua ante...

Page 9: ...productos utilizados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comuníquese con el Departamento de Atención al Cliente de CountyLine Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminación Si su bomba cloacal ha fallado Use guantes de caucho cuando ...

Page 10: ... forma el tanque Ciclo de operación 1 El tanque está casi vacío el aire se xpande llenando el área por encima de la cisterna Figura 2A 2 El agua entra en el tanque el aire se comprime por encima de la cisterna a medida que se llena de agua Figura 2B 3 Se ha completado el ciclo de bombeo el aire comprimido para la graduación OFF apagado del conmutador a presión Figura 2C 4 Aspiración adicional desd...

Page 11: ...evas instalaciones bombas que se deben volver a cebar y bombas que se han desarmado para servicios de mantenimiento o reparaciones Se debe realizar lo siguiente 1 Abra los grifos más lejanos al tanque y haga funcionar la bomba 2 Haga funcionar la bomba hasta que no haya más chisporroteo y se observe una corriente continua de agua 3 Abra y cierre los grifos repetidamente hasta que se haya eliminado...

Page 12: ...s separados de entrada y de salida Los tanques precargados poseen un orificio para ambas funciones Cuando sustituya un tanque estándar con un tanque precargado haga correr un tubo desde la bomba hacia el tubo en T según se ilustra La segunda pata del tubo en T va al codo del tanque la tercera pata va al servicio ya existente To service Pressure Relief Valve Pressure Gauge Pressure Switch From Well...

Page 13: ...CLPT36 CLPT52 CLPT85 CLPT119 No cuentan con soporte de bomba Instale la bomba al lado del tanque Ref Descripción Cant CLPT20 CLPT36 CLPT52 CLPT85 CLPT119 1 Cubierta de la válvula de aire 1 U31 380P 2 Valvula de aire con tapa 1 U212 160 3 Cisterna vinilo 1 U20 13 U20 9 U20 10 U20 14 U20 20 4 Reborde cobertor y codo 1 U31 446P U31 447P U231 462P 5 Tuerca de bridas 5 16 18 6 U36 202BT 6 Base 1 U31 50...

Page 14: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 15: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 16: ......

Reviews: