Version 1.0
Page 31
INSTALLATION / MOBILE HOME STANDARDS
1.
Mobile home code requires the pellet stove be bolted to the floor regardless of whether it has
legs or is mounted on its optional pedestal.
2.
A pellet stove must be electrically grounded to the steel frame of the mobile home.
3.
A pellet stove must have an outside combustion air source installed in a mobile home.
4.
CAUTION:
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME (floors, walls,
ceilings and roof) MUST BE MAINTAINED.
5.
WARNING:
DO NOT INSTALL A PELLET STOVE IN A SLEEPING AREA.
6.
Check any other local building codes as they apply.
BOLT
LEGS TO
FLOOR
FIGURE 11: MOBILE HOME LEG INSTALLATION
BOLT PEDESTAL
TO FLOOR
FIGURE 12: MOBILE HOME PEDESTAL INSTALLATION