Cleaning
Page 8
Operation & Maintenance Manual - Vision Chilled Displays
…flat surface protected by soft cloths. The glass ends can then be slid forward until they release from the channels, when
they can be lifted clear of the unit and set aside on a surface protected by soft cloths. They can then be cleaned on both
sides.
Note: It is essential that safety glasses are worn when removing any pieces of glass.
•
Remove any food debris using a vacuum cleaner suited to wet use, followed by a cloth and detergent.
•
Wipe the fan blades using a damp cloth and detergent.
•
Finally spray the interior of the tank and the finned cooling coil generously with a sanitising solution such as Dettox.
•
Avoid using excess water if your unit is not connected to a plumbed drain, as this may cause the automatic evaporating
drip tray to overflow.
•
Re-assembly is the reverse of the above.
When cleaning the unit you must inspect the main cooling coil. You should find the coil covered with a thin layer of frost or
ice. Anything up to about 2mm thick is quite normal but anything in excess of this seriously impairs its efficiency.
Note: If there is a build up of ice refer to section 3
TILT GLASS BACK SLOWLY
UNTIL HINGE LOCKS IT IN
PLACE
HINGE POINT
(STANDALONE UNIT ILLUSTRATED)