COUNTERFOG® PILAR
User Manual
COUNTERFOG® EBT de la UAH S.L.
20
o
Tilt the
Counterfog® PILAR
slightly to both sides so as to drinkable
water is being mixed with the remaining disinfectant in the walls of the
device.
o
To evacuate the remaining liquid from
Counterfog® PILAR
, place a
suitable container (compatible with the disinfectant) under the device
since the residual disinfectant will come out through the Teflon hose
indicated in the following image.
o
Open valve 4 (
open
4 “EMPTY”
) and the liquid is evacuated.
Always wear gloves and safety glasses when evacuating the
residual liquid from the device!
o
When finish evacuating liquid, close valve 4 (
close
4 “EMPTY”
).
o
Screw the cap to the funnel (
screw 12
).
o
Open the vent valve (
Open
11 “VENT”
).
o
Open the filling valve (
Open
3 “FILL”
), open the empty valve (
OPEN 4
“EMPTY”)
and check the other valves remain closed
(6 “LIQUID “and
7 “AIR”
closed).
o
Plug the equipment
to the 120 V/60 Hz supply line.
o
Activate the switch on the left (
Activate switch 1
) (
yellow arrow in
the figure
) which activates the fan.
o
Activate the switch on the right (
Activate switch 2
) (
green arrow in
the figure
) which activates the compressor.
Please, follow the correct order of activation of the switches.