The fog cone must be projected under and behind furniture. All directions in the room
must be swept. A few minutes should be enough to disinfect a standard-sized room.
After the disinfection process, the disinfected surfaces will be "slightly moist".
7.
PAUSE
Disinfection can be paused just closing the liquid valve (
Close 5
) and the air valve (
Close
9
).
If after the pause you want to continue the disinfection, follow (in order) the next
steps:
Hold firmly the Counterfog® MPM Nozzle (
hold 17
) pointing at the floor.
Open the air valve (
Open 9
).
Open the liquid valve (
Open 5
).
Proceed to disinfection-decontamination.
8.
END OF OPERATION
When wanted to finish disinfection, follow the next steps.
o
Close the liquid valve (
Close 5
).
o
Close the air valve (
Close 9
).
o
Switch
OFF
the COUNTERFOG® PILAR 2.0 (position 0). See next image.