ChargePoint® Charging Stations
2-8
Step 6 - Connect wires to wiring terminals
Pull the 240V L1 and L2 wires, and the
Ground wire, into body assembly and
connect to wiring terminals.
Strip wires ¼” (6 mm), insert in
terminal block, and tighten screws to
18
½
inch-lbs (2.1 Nm).
IMPORTANT:
• Requires dedicated 40A breaker.
• Use copper conductors only.
• Do NOT provide GFCI protection at
panel. The CT500 has built-in GFCI
protection.
• In areas with frequent thunder
storms, add surge protection at the
service panel for all circuits.
Before proceeding with the next step,
test the unit by restoring power. When
the circuit is live, you should see a
sequence of power-up message on the
CT500’s display. If this is not the case,
turn off power and check the wiring
connections.