Cotek BP-1205 User Manual Download Page 9

 

3-1-2.ON / OFF switch

 

Power ON / OFF switch, leave the status OFF during installation. 

3-1-3.LED Status 

Charging Status 

LED Indication 

Fast Charge 

Fast Green Blink 

Slow Charge 

Slow Green Blink 

Floating Charge 

Solid Green 

Charging Failure 

Red Blink 

Bad Battery or Wire Disconnection

Red Blink 

3-2. Rear Panel Operation

 

STATUS

     D C  

O U T P U T

PUSH

FUSE

  DC 

 

3-2-1.Ventilation Shaft

 

Be sure to keep it a distance (at least one inch) from surrounding 
things. 

3-2-2.DC Output Terminals

 

Connect it to 12V/24V batteries. 

+

indicates positive, 

-

indicates negative.    Reverse polarity  

connection will blow the internal fuse and may damage BP-

□□□□

 

permanently. 
 

 

 

 

文管中心 

發行章 

Summary of Contents for BP-1205

Page 1: ...BP Series Switch Mode 3 Stage Battery Charger User s Manual...

Page 2: ...Curve 3 2 2 Electrical Characteristics 4 2 3 Mechanical Drawing 5 3 Instructions 6 3 1 Front Panel Operation 6 3 2 Rear Panel Operation 7 3 3 Troubleshooting 8 3 4 Battery Type Selections 8 DCopyrigh...

Page 3: ...artment Overheating may occur 1 1 2 To avoid the risk of fire and electronic shock make sure that existing wiring is in good electrical condition and not undersize Do not operate BP Battery Charger wi...

Page 4: ...mmediately 1 2 2 Never smoke or make a spark or flame in the vicinity of the battery or the engine 1 2 3 Do not drop metals on the battery The resulting spark or short circuit on the battery or other...

Page 5: ...or Advanced 8 bit microprocessor control circuit Reverse polarity protected by fuse Ignition protection Output short circuit protection Over power protection Switch mode technology Statue of charge in...

Page 6: ...s A EN61000 3 3 1995 A1 2001 Dimensions 210 L x 85 W x 50 H mm 8 26 L x 3 34 W x 1 96 H Inch Weight 1 kgs 2 2 Lbs Specification Technical Data Model No BP 2403 BP 2405 Input Voltage 100 240VAC 50 60Hz...

Page 7: ...BSOR BLINKING SLOW FLOATING SOLID CHARGING FAULT WIRE DISCONNECTION BAD BATTERY AC IN 100 240VAC 50 60Hz PF0 98 DC OUT 12V DC 5A MAX 50 210 85 POS NEG PUSH 0 I 0N 0FF 3 STAGE HIGHTECH BATTERY CHARGER...

Page 8: ...controller and PFC circuit to manage battery intelligently and to provide highly reliable operations Before using BP read all instructions and precautions marking on this manual 3 1 Front Panel Opera...

Page 9: ...reen Charging Failure Red Blink Bad Battery or Wire Disconnection Red Blink 3 2 Rear Panel Operation STATUS DC OUTPUT PUSH FUSE DC 3 2 1 Ventilation Shaft Be sure to keep it a distance at least one in...

Page 10: ...output fuse LED light off No AC power delivering Check input power connection Thermal shutdown Make sure the ventilation shaft is not obstructed Improve ventilation Lower the temperature Surrounding i...

Page 11: ...No 33 Rong Hsin Rd Pa Teh City Tao Yuan County Taiwan Phone 886 3 3661581 FAX 886 3 3676029 E mail sales cotek com tw http www cotek com tw 2005 08...

Reviews: