3-3. Troubleshooting

 

Problems and Symptoms 

Possible Cause 

Solutions 

 “Red” LED blink 

Battery is disconnected

Check the battery  

  connection. 
 

 

 

 

Polarity reverse 
 

 

Place proper polarity. 
Check DC fuse. If 
broken, replace the 
same rating fuse. 
 

 

DC fuse broken 

Check DC output fuse 

 

 

 

 LED light off 

No AC power delivering

Check input power 

  connection. 

 Thermal 

shutdown 

 

Make sure the 
ventilation shaft is 

  

 

not 

obstructed. 

  

 

Improve 

ventilation. 

 

 

 

Lower the temperature 

 

 

 

Surrounding it. 

 

3-4. Battery Type Selections

 

Sealed lead acid and open lead acid batteries are as follows

 

Model No. 

Battery Capacity (Min.) 

Battery Capacity (Max.) 

BP-1205 

12V / 15Ah 

12V / 50Ah 

BP-1210 

12V / 30Ah 

12V / 100Ah 

BP-2403 

24V / 7.5Ah 

24V / 25Ah 

BP-2405 

24V / 15Ah 

24V / 50Ah 

 

 

8

 

 

文管中心 

發行章 

Summary of Contents for BP-1205

Page 1: ...BP Series Switch Mode 3 Stage Battery Charger User s Manual...

Page 2: ...Curve 3 2 2 Electrical Characteristics 4 2 3 Mechanical Drawing 5 3 Instructions 6 3 1 Front Panel Operation 6 3 2 Rear Panel Operation 7 3 3 Troubleshooting 8 3 4 Battery Type Selections 8 DCopyrigh...

Page 3: ...artment Overheating may occur 1 1 2 To avoid the risk of fire and electronic shock make sure that existing wiring is in good electrical condition and not undersize Do not operate BP Battery Charger wi...

Page 4: ...mmediately 1 2 2 Never smoke or make a spark or flame in the vicinity of the battery or the engine 1 2 3 Do not drop metals on the battery The resulting spark or short circuit on the battery or other...

Page 5: ...or Advanced 8 bit microprocessor control circuit Reverse polarity protected by fuse Ignition protection Output short circuit protection Over power protection Switch mode technology Statue of charge in...

Page 6: ...s A EN61000 3 3 1995 A1 2001 Dimensions 210 L x 85 W x 50 H mm 8 26 L x 3 34 W x 1 96 H Inch Weight 1 kgs 2 2 Lbs Specification Technical Data Model No BP 2403 BP 2405 Input Voltage 100 240VAC 50 60Hz...

Page 7: ...BSOR BLINKING SLOW FLOATING SOLID CHARGING FAULT WIRE DISCONNECTION BAD BATTERY AC IN 100 240VAC 50 60Hz PF0 98 DC OUT 12V DC 5A MAX 50 210 85 POS NEG PUSH 0 I 0N 0FF 3 STAGE HIGHTECH BATTERY CHARGER...

Page 8: ...controller and PFC circuit to manage battery intelligently and to provide highly reliable operations Before using BP read all instructions and precautions marking on this manual 3 1 Front Panel Opera...

Page 9: ...reen Charging Failure Red Blink Bad Battery or Wire Disconnection Red Blink 3 2 Rear Panel Operation STATUS DC OUTPUT PUSH FUSE DC 3 2 1 Ventilation Shaft Be sure to keep it a distance at least one in...

Page 10: ...output fuse LED light off No AC power delivering Check input power connection Thermal shutdown Make sure the ventilation shaft is not obstructed Improve ventilation Lower the temperature Surrounding i...

Page 11: ...No 33 Rong Hsin Rd Pa Teh City Tao Yuan County Taiwan Phone 886 3 3661581 FAX 886 3 3676029 E mail sales cotek com tw http www cotek com tw 2005 08...

Reviews: