Troubleshooting guide
Problem
Possible cause
Possible solution
The pump runs but does
not pump.
• Air in pump, outlet is blocked.
• Air trapped in suction pipe.
• Pump is blocked.
• When the pump starts the
water level falls to below the
minimum level.
• Clean the hose, straighten any kinks, etc.
• Wait 60 seconds until the pump is purged of
air, switch it off and then start it again.
• Unplug the pump from the power supply and
remove any debris from the water inlet (6).
• Place the pump lower in the water.
The pump will not start
or stops under load.
• The thermal protection
device has tripped.
• No power supply.
• Dirt lodged in the pump.
• Unplug and clean the pump. Remember that
the max liquid temperature is 35 ˚C.
• Check fuses and RCD, etc.
• Unplug the pump from the power supply and
remove any debris from the water inlet (6).
The pump runs but the
volume pumped falls
suddenly.
• Pump is blocked.
• Unplug the pump from the power supply and
remove any debris from the water inlet (6).
Pump does not stop when
water level has sunk.
• The float is prevented
from falling.
• Place the pump so that the float
can move freely.
Disposal
Dispose of your waste responsibly, sort and recycle where possible. All machines, hoses and packing material
should be sorted and handled according to local environmental regulations.
Specifications
Rated voltage
230 V AC, 50 Hz
Power
1100 W
Pump Capacity
6,000 l/h
Pressure Head
45 m
Submersible Depth
8 m
Max. Particle Size
1 mm
Max. Water Temperature
35 °C
Hose connection
25 mm (1
″
)
Union Thread
Female (1
″)
Length of Power Lead
10 m (H07RN-F)
Size
16 × 43 cm
Weight
10.3 kg