![Cotech GG3300B Original Instructions Manual Download Page 12](http://html1.mh-extra.com/html/cotech/gg3300b/gg3300b_original-instructions-manual_2672611012.webp)
12
EN
GL
IS
H
Troubleshooting guide
The engine will not start.
• The engine switch is set to
OFF
.
• Check that there is fuel and the fuel cut-off valve is open.
• Is the choke set to
CHOKE
?
• Check the oil level. If the oil level is low, the oil level safety cut-off switch
will prevent the generator from starting.
• The air filter is clogged.
The engine will run but
the generator will not
produce electricity. Connected
devices will not work.
• The AC on/off switch (17) is set to
OFF
.
• Make sure that the overvoltage cut-off has not tripped.
• Make sure that the devices are not faulty, are properly connected to
the generator and that the cables are in good condition.
Disposal
This product should be disposed of in accordance with local regulations.
If you are unsure how to proceed, contact your local authority.
Specifications
Engine
Single-cylinder, 4-stroke, OHV
Power
7 hp
Fuel capacity
15 l
Operating time
approx. 11 hours
Engine oil
SAE 10W-30
Oil capacity
0.6 l
Spark plug
F6TC (NGK BP7ES, Bosch WR5DC, Champion N7YC)
Output voltage
230 V, 50 Hz and 12 V
230 V load capacity
Running 2600 W, Surge 3000 W
12 V load capacity
8.3 A
Noise level LwA
96 dB(A)
Size
60 × 45 × 46 cm
Weight
42 kg