(1) A primary power supply cable is available for this welding machine.
Connect the power supply cable to the rated input power.
(2) The primary cable should be tightly connected to the correct socket to
avoid oxidization.
(3) Check whether the voltage value varies in acceptable range with a
multi-meter.
(4) Insert the cable plug with electrode holder into the “+” socket on the
front panel of the welding machine, and tighten it clockwise.
(5) Insert the cable plug with work clamp into the “
-
” socket on the front
panel of the welding machine, and tighten it clockwise.
(6) Ground connection is needed for safety purpose.
Operation:
1.Put the switch to ON and then LCD would show, and fan is working and
welder is in normal working status.
2. Users could select suitable welding current according to the working
plate’s thickness, electrodes diameters, etc.
3. Clamp the electrode to electrode holder and scratch the arc to start
welding. (Working amp could be read on the LCD display)
Please note that this parameters is mainly for low carbon steel
welding.
5. Installation and Operation
07