ON/OFF AIR SWITCH

Some whirlpool baths pumps are equipped with an on-off air switch. Each 
depression of the switch will actuate the pump. If off, one depression will turn the 
pump on, if on, the next depression will turn it off.

Blower

Speed

Wave

Jets

Speed

Wave

Switches the 

jet-pump on or off

Adjusts the variable 
water-flow of the jets

Switches from continuous 
to wave action water-flow

Switches the 
air-blower on or off

Adjusts the variable
air-flow of the blower

Switches from continuous 
to wave action air-flow

Illustration J

TOTAL MASSAGE BATHS

Total Massage units are a combination of whirlpool and air massages. The top three controls on the “Therapy 
Control Center” operate the whirlpool and the bottom three controls operate the air system. The whirlpool and 
air massage systems may be used at the same time if desired. 

The whirlpool is controlled by the top three-button control. 

1.  The button on the left switches the pump on or off. The other features will not operate unless the pump is 

turned on.

2.  The middle button sets the power level of the pump. Holding the button depressed will cycle the pump 

power from low to high in a continuous cycle. When the desired level is reached, remove your finger quickly 
from the button to maintain that power setting. 

3.  The button on the right is a three-step wave action button: 

a. Position #1 operates the pump at a steady flow. 
b. Position #2 operates the pump at a quick wave action.  
c. Position #3 operates the pump with a slower wave action.

The air bath is controlled by the bottom three-button control.

1.  The first button switches the blower on or off. The other features will not operate unless the blower is 

turned on.

2.  The second button sets the power level of the blower. Holding the button depressed will cycle the blower 

power from low to high in a continuous cycle. When the desired level is reached, remove your finger quickly 
from the button to maintain that power setting. 

3.  The third button is a three-step wave action button. Once activated, the air holes expel air in a slow 

pulsating flow called wave action. There are 3 steps or positions for wave strength. 
a. Position #1 operates the blower at a steady flow. 
b. Position #2 operates the blower at a quick wave action. 
c. Position #3 operates the blower at a slower wave action. 

Summary of Contents for the estate 507187

Page 1: ... Z124 1 9 ASME A112 IAPMO AND UL 1795 INSTALLER IS RESPONSIBLE FOR COMPLYING WITH LOCAL CODES THAT MAY APPLY LICENSED PLUMBERS AND ELECTRICIANS SHOULD BE EMPLOYED TO INSURE PROPER INSTALLATION INSTALLERS ASSUME ALL LIABILITY FOR FOLLOWING THE CORRECT INSTALLATION PROCEDURES USE ONLY ACCESSORIES AUTHORIZED BY THE MANUFACTURER WITH THIS PRODUCT THIS PRODUCT IS DESIGNED FOR USE BY HEALTHY INDIVIDUALS...

Page 2: ...MAY BE INJURIOUS TO YOUR HEALTH CHECK AND ADJUST WATER TEMPERATURE BEFORE USE WARNING RISK OF HYPERTHERMIA PEOPLE USING MEDICATIONS AND OR HAVING AN ADVERSE MEDICAL HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A HYDRO MASSAGE BATHTUB PROLONGED IMMERSION IN WATER HOTTER THAN NORMAL BODY TEMPERATURE MAY INDUCE HYPERTHERMIA TEST THE WATER TEMPERATURE AND ADJUST THE HOT AND COLD VALVES TO REACH A W...

Page 3: ...PRECAUTIONS READ AND FOLLOW ALL INSTRUCTIONS PERTAINING TO RISK OF FIRE ELECTRIC SHOCK OR INJURY DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised Use this unit only for its intended purpose as described in this bulletin Do not use attachments that are not recommended by the manufacturer Never drop or insert any objects into any openi...

Page 4: ...ration E 12 11 DRAIN CLEARANCE PUMP ACCESS DRAIN CLEARANCE MEASURE FROM THE FLOOR TO THE STRAIGHT EDGE THROUGH THE DRAIN HOLE TO OBTAIN A CONSISTENT HEIGHT TO DECK DIMENSION INSTALLATION PLANNING AND PREPARATION 1 BATH TUBS MUST BE SET IN SETTING COMPOUND An uneven floor can impede installation 2 NEVER LIFT THE TUB BY THE PLUMBING Doing so can result in leaks 3 Check if the floor is level and of g...

Page 5: ...ers A setting compound such as cement or mortar must support the tub bottom A sheet of plastic film both under and on the top of the compound is recommended as a barrier The tub should be set in place do not handle the whirlpool by the piping while the compound is still soft so that the compound will conform to the tub bottom The tub should be worked down into the compound until the lip of the tub...

Page 6: ...WIRE BRUSHES OR OTHER HARSH ABRASIVE TOOLS Usually a mild detergent will remove construction debris More stubborn debris may be removed with denatured alcohol or Clorox Soft Scrub cleaner Light scratches and dulled areas may be restored to original luster by rubbing with an automotive type cleaning compound such as DuPont White Polishing Compound OPERATING INSTRUCTIONS 1 Fill the bath at least to ...

Page 7: ...ower level of the pump Holding the button depressed will cycle the pump power from low to high in a continuous cycle When the desired level is reached remove your finger quickly from the button to maintain that power setting 3 The button on the right is a three step wave action button a Position 1 operates the pump at a steady flow b Position 2 operates the pump at a quick wave action c Position 3...

Page 8: ...cotton buffing pad or equivalent Use an extra application of fine buffing compound if necessary For Cracks and Major surface damage call our service line 800 426 8964 WHIRLPOOL TROUBLE SHOOTING MOTOR WILL NOT START 1 Check Circuit Breakers 2 Check for incorrect or loose wire connections 3 Make sure the correct power supply is being used 4 Electronic On Off switch should be in the On mode 5 Make su...

Page 9: ...Systems No warranty expressed or implied including any warranty of merchantability or fitness for a particular purpose shall apply after the warranty period described above Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts The above limitation may not apply to you In the event of a defect in material or ...

Page 10: ...57 8 4 49 8 37 8 60 36 31 5 3 5 55 5 6 0 6 0 48 25 507190 507187 2 5 8 5 2 5 8 5 507193 4 5 Whirlpool Tub Cut Out Templates ...

Reviews: