background image

INSTALLING AN OVAL TUB WITH A TEMPLATE DIAGRAM

Refer to illustration D. The back section of this manual contains oval cut out instructions. Use pencil and tape 
measure to plot the coordinates and draw the cut out. Take special care that you do not to drop the tub in the 
platform cutout, since the tub may break and the ensuing warranty limitations would become effective. For 
additional questions on installing the tub read “installation procedures” above. 

CLEANING AND MAINTENANCE

Air Baths are equipped with an Automatic Cleaning and Purge Cycle

Air Baths have a pre-programmed cleaning and purge cycle built in to expel the remaining water in the air 
channels. 

It activates within 20 minutes after the Air Bath is turned off and then blows for about 2 to 3 

minutes

. After the cycle is completed it will shut off automatically. There is nothing to be alarmed about if you 

hear a blowing noise coming from the tub after the tub has been turned off. The noise you hear is the cleaning 
cycle in operation.
Pump and hose circulation system should be flushed before first use and on a monthly basis when product is 
under normal use. Below are the recommended procedures for cleaning:
•  

DO NOT RUN WHIRLPOOL DRY

. Fill the tub with hot water 2-3 inches above the jets and add 2-3 

tablespoons of Lysol™, Pine sol™ or similar detergents. 

• Switch on whirlpool and run for 10 minutes.
• Drain tub completely.
• Fill tub with cold water above jets.
• Switch on whirlpool and run for 5 minutes.
• Drain tub completely.

DO NOT USE ABRASIVE CLEANERS

 as they will scratch and dull the surface of the acrylic.

Plaster can be removed using a sharpened wooden stick. 

DO NOT USE METAL SCRAPERS, WIRE 

BRUSHES OR OTHER HARSH ABRASIVE TOOLS

. Usually a mild detergent will remove construction 

debris. More stubborn debris may be removed with denatured alcohol, or Clorox Soft Scrub® cleaner. Light 
scratches and dulled areas may be restored to original luster by rubbing with an automotive type cleaning 
compound such as DuPont White Polishing Compound®.

OPERATING INSTRUCTIONS

1.  Fill the bath at least to 3 inches above the jets before activating the pump.
2.  The air bath blower and/or whirlpool pump is activated by depressing the control panel buttons. Do not 

repeatedly depress the switch in rapid order if you do not see the whirlpool function right away, as it may 
take a few seconds before you can see it fully operating. Please see air bath control or Total Massage 
Control instructions on the following page for operation and features. 

3.  If any factory-installed fittings are removed; do not operate the unit. A safety hazard may occur.
4.  Do not use bubble bath when you operate the whirlpool pump. This might cause excessive foaming.
5.  Bath oils may be used; however their frequent use will require more frequent purging and cleaning of the 

systems.

6.  Both air and whirlpool systems are plumbed in a way that water will drain from the plumbing easily.
7. There are no user serviceable parts located under the tub.

JET OPERATION AND ADJUSTMENT 

The jets are easily adjusted by pointing the jet-nozzle in the desired direction. The 
strength of the water flow and air induction can be regulated through twisting the 
jet-nozzle. Turning the nozzle clockwise will decrease the water flow and finally 
completely turn off the water flow of that particular jet. If the nozzle is turned counter 
clockwise then the water flow will increase up to its maximum flow. Only a 1/4 turn or 
90˚ turn is required from the OFF position to the fully OPEN position.

Illustration I

Summary of Contents for the estate 507187

Page 1: ... Z124 1 9 ASME A112 IAPMO AND UL 1795 INSTALLER IS RESPONSIBLE FOR COMPLYING WITH LOCAL CODES THAT MAY APPLY LICENSED PLUMBERS AND ELECTRICIANS SHOULD BE EMPLOYED TO INSURE PROPER INSTALLATION INSTALLERS ASSUME ALL LIABILITY FOR FOLLOWING THE CORRECT INSTALLATION PROCEDURES USE ONLY ACCESSORIES AUTHORIZED BY THE MANUFACTURER WITH THIS PRODUCT THIS PRODUCT IS DESIGNED FOR USE BY HEALTHY INDIVIDUALS...

Page 2: ...MAY BE INJURIOUS TO YOUR HEALTH CHECK AND ADJUST WATER TEMPERATURE BEFORE USE WARNING RISK OF HYPERTHERMIA PEOPLE USING MEDICATIONS AND OR HAVING AN ADVERSE MEDICAL HISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A HYDRO MASSAGE BATHTUB PROLONGED IMMERSION IN WATER HOTTER THAN NORMAL BODY TEMPERATURE MAY INDUCE HYPERTHERMIA TEST THE WATER TEMPERATURE AND ADJUST THE HOT AND COLD VALVES TO REACH A W...

Page 3: ...PRECAUTIONS READ AND FOLLOW ALL INSTRUCTIONS PERTAINING TO RISK OF FIRE ELECTRIC SHOCK OR INJURY DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised Use this unit only for its intended purpose as described in this bulletin Do not use attachments that are not recommended by the manufacturer Never drop or insert any objects into any openi...

Page 4: ...ration E 12 11 DRAIN CLEARANCE PUMP ACCESS DRAIN CLEARANCE MEASURE FROM THE FLOOR TO THE STRAIGHT EDGE THROUGH THE DRAIN HOLE TO OBTAIN A CONSISTENT HEIGHT TO DECK DIMENSION INSTALLATION PLANNING AND PREPARATION 1 BATH TUBS MUST BE SET IN SETTING COMPOUND An uneven floor can impede installation 2 NEVER LIFT THE TUB BY THE PLUMBING Doing so can result in leaks 3 Check if the floor is level and of g...

Page 5: ...ers A setting compound such as cement or mortar must support the tub bottom A sheet of plastic film both under and on the top of the compound is recommended as a barrier The tub should be set in place do not handle the whirlpool by the piping while the compound is still soft so that the compound will conform to the tub bottom The tub should be worked down into the compound until the lip of the tub...

Page 6: ...WIRE BRUSHES OR OTHER HARSH ABRASIVE TOOLS Usually a mild detergent will remove construction debris More stubborn debris may be removed with denatured alcohol or Clorox Soft Scrub cleaner Light scratches and dulled areas may be restored to original luster by rubbing with an automotive type cleaning compound such as DuPont White Polishing Compound OPERATING INSTRUCTIONS 1 Fill the bath at least to ...

Page 7: ...ower level of the pump Holding the button depressed will cycle the pump power from low to high in a continuous cycle When the desired level is reached remove your finger quickly from the button to maintain that power setting 3 The button on the right is a three step wave action button a Position 1 operates the pump at a steady flow b Position 2 operates the pump at a quick wave action c Position 3...

Page 8: ...cotton buffing pad or equivalent Use an extra application of fine buffing compound if necessary For Cracks and Major surface damage call our service line 800 426 8964 WHIRLPOOL TROUBLE SHOOTING MOTOR WILL NOT START 1 Check Circuit Breakers 2 Check for incorrect or loose wire connections 3 Make sure the correct power supply is being used 4 Electronic On Off switch should be in the On mode 5 Make su...

Page 9: ...Systems No warranty expressed or implied including any warranty of merchantability or fitness for a particular purpose shall apply after the warranty period described above Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts The above limitation may not apply to you In the event of a defect in material or ...

Page 10: ...57 8 4 49 8 37 8 60 36 31 5 3 5 55 5 6 0 6 0 48 25 507190 507187 2 5 8 5 2 5 8 5 507193 4 5 Whirlpool Tub Cut Out Templates ...