Installation Manual
8.0 Best Practices
8.0
Best
Practices
The
purpose
of
this
section
is
to
provide
recommendations
regarding
the
proper
selection
and
use
of
Surge
Protection
Devices
(SPDs)
in
CCTV
systems.
This
section
is
not
meant
to
provide
guidance
for
SPDs
selection,
placement,
and
use
on
incoming
utility
power.
Always
follow
local
and
national
electric
code
and
refer
to
licensed
electricians
or
other
trained
professionals
for
guidance.
Surge
Protection
Devices
are
designed
to
prevent
damage
to
equipment
caused
by
transient
voltages
from
a
number
of
possible
sources.
Due
to
their
exposure
to
the
environment,
when
planning
the
installation
of
a
Co
star
HD
camera
system,
SPDs
must
be
appropriately
installed.
Depending
on
the
exact
equipment
being
installed,
one
or
more
SPD
types
must
be
used
to
properly
protect
from
damage
caused
by
electrical
surge.
There
are
several
types
of
SPDs:
l
AC PowerSPDs
l
EthernetSPDs
l
Power over Ethernet (PoE) SPDs
l
AnalogVideoSPDs
l
LowVoltageDC(SerialData)SPDs
Each SPD type is designed for a specific application and is only rated to work within the nominal voltage
levels of that application. To provide protection, it is critical that the SPD for your application be of the appro-
priate type and ratings. Refer to the SPD manufacturer for proper device selection for your application.
Placement of SPDs is critical. Per IEEE, NEMA, and industry guidelines, an SPD should be installed within
four feet of the equipment it is protecting. Additionally, SPDs should be installed at each end of all cables
greater than thirty feet in length. In most CCTV applications, this means that a minimum of two SPDs must be
used: one near the camera, and one in the control cabinet that provides network connectivity and power.
Proper orientation is key on many SPDs as they often have PROTECTED and UNPROTECTED terminals,
or DEVICE and LINE terminals. For a typical CCTV application, the UNPROTECTED or LINE terminals
should be used to connect the upper and lower SPDs, while the PROTECTED or DEVICE terminals should
connect to the camera and network switch (or PoE injector). An incorrectly oriented SPD will appear to func-
tion as voltage will still pass through it, however when installed backwards, the device will not provide full pro-
tection. Always verify the orientation of each SPD and contact the manufacturer for assistance.
Lastly, an SPD can only function if it is properly grounded. Unless a lower value is required to meet your local
or project-specific specifications, the grounding array that the SPD is connected to should be no more than
10Ω. All wiring from the ground connection of the SPD should be as short and straight as possible, and all con-
nections should be properly crimped and securely fastened.
17
Summary of Contents for 3490HD Series
Page 2: ......
Page 4: ......
Page 19: ...Installation Manual 9 0 Installation 9 1 Typical Wall Mount Installation 19 ...
Page 20: ...Installation Manual 9 0 Installation 9 2 Typical Pole Mount Installation 20 ...
Page 27: ......
Page 28: ...Installation Manual For more information please visit us at www CostarHD com 28 ...