Installation Manual
7.0 Connections
2. If the RJ45 plug has a strain-relief boot, push it away from the RJ45 plug. The strain-relief boot will not
be used.
3. Pass the cable through the Sealing Nuts
j
.
4. Pass the cable through the Sealing Collar
.
5. Insert the Washer
m
and the Two-Way RJ45 Port
n
in the Coupler Body
l
(if disassembled).
6. Insert the RJ45 plug into the Coupler Body
l
.
7. Attached the Sealing Collar
to the Coupler Body
l
. Make sure it is tightened completely.
8. Select the desired Seal
k
(typically small diameter cable), and press to open notch.
9. Insert the Seal
k
onto the cable with the recessed surface facing the Sealing Collar
, then push the
Seal all the way into the Sealing Collar.
The Seal should sit completely flushed inside the fingers of the Sealing Collar with edge not protruding.