Installation and Testing Procedures

• Remove all packaging material and inspect system thoroughly to ensure that no damage has 

occurred during handling/transportation. In the event of damage due to shipping, 
immediately notify the freight carrier so that an appropriate claim may be filed with the carrier.

• Select installation location in accordance with the instructions stated in the “Location”

section of this manual (Page 5). When selecting location, consideration must be given to
the proximity of the electrical and plumbing connections.

• Electrical and plumbing connections can now be made in accordance with location 

plumbing and electrical codes. Refer to “Electrical Rating”, “Electrical and Plumbing
Connection” sections contained in this manual for technical support information
(See Pages  5 - 8) 
Plumbing codes vary from location to location and may require the installation of check 
valves (back-flow prevention valves) on incoming hot and cold water supply lines and/or 
sanitary drain connections. Due to the variations in plumbing codes, this system is not 
supplied with these valves. Please arrange for your plumbing contractor to install the 
appropriate devices as required to meet your local codes.

NOTE: ANY METAL PLUMBING PROVIDED DURING INSTALLATION MUST BE 
BONDED WITH A #8 AWG WIRE TO THE SAME BONDING GRID AS THE SANIJET

®

MOTORS.

• Once the electrical and plumbing connections are made, the system should be filled 

with water and tested so that all plumbing and fitting can be inspected prior to fitting
the enclosure skirt.

WARNING: WHEN WATER TESTING THE SYSTEM, AND BEFORE FILLING THE 
SYSTEM WITH WATER, ALL ELECTRICAL ENCLOSURE BOXES MUST BE CLOSED 
AND COVERS SECURED, TO PREVENT WATER INFILTRATION SHOULD LEAKS 
OCCUR.

• Before filling the Biarritz™ with water, ensure the basin is clean and that no debris or other 

foreign matter is inside the basin that could cause blockage of jets when the system is 
operated, damage to the hydro-jets system, or scratches to the basin’s acrylic surface.

• Test the system by filling the basin until water reaches approximately 1” (25 mm) higher

than the highest jets. This will avoid water being expelled from the Biarritz™ when
system is activated (See Photo #8 below). NOTE: The basin drain (See Photos #23-24, 
Pg.22) must be in the closed position prior to filling.

Fill Level

Fill Jet 

Photo #8

Product Code: LM917135

www.spaequip.com

P: 707.737.1100 F: 707.737.1150

Page 11 of 18

Summary of Contents for LM917135

Page 1: ...the water pump is included in each assembly there is no internal piping to allow stagnant water or bacteria buildup Marine grade vinyl fabric shown in Teak is available in wide range of colors 110V AC...

Page 2: ...General Overview 3 Biarritz Installation Manual v 1 3 Photo 1 11 10 6 8 7 3 4 9 5 2 12 12 1 13 14 Product Code LM917135 www spaequip com P 707 737 1100 F 707 737 1150 Page 2 of 18...

Page 3: ...otrest Height Adjusting Hand Screw 6 Footrest Receiver 7 Thermostatic Control Valve 8 Jet Pump On Off Control 9 Removable Lower Skirt Assembly 10 Seat Horizontal Adjustment 11 Seat Reclining Back Adju...

Page 4: ...ing codes Hot and cold supply connections are made by means of 3 4 inch 19 mm compression fittings provided Incoming supply connections should be made in accordance with local and national plumbing co...

Page 5: ...plumbing code requirements IMPORTANT NOTE We recommend the use of anti slip graded tiles on surrounding floor surfaces This important recommendation will ensure a safe environment for therapists and c...

Page 6: ...AL ELECTRICAL CODES The branch circuit supplying this system must be provided with a main disconnect in the fixed wiring NOTE Outside of North America a GFCI may be referred to as an earth leakage cir...

Page 7: ...n request circuit diagrams component parts lists descriptions calibration instructions or other information which will assist the user s technical personnel to repair those parts of the equipment whic...

Page 8: ...ed nuts and washers 4 each install from the underside and secure tighten using a 1 2 13mm deep well socket and ratchet assembly Note 8 mm hardware nuts are included within your packaging Photo 6 4 Ele...

Page 9: ...unit during installation Leveling feet also are designed to elevate the system and provide an adequate ventilation area by providing an air gap between the bottom of the covering or skirt and the floo...

Page 10: ...ed plumbing contractor to install the appropriate devices as required to meet local codes 34 86 4 cm FRONT Plumbing and Electrical Layout 73 185 4 cm In the reclined position Electrical 115V N America...

Page 11: ...s Please arrange for your plumbing contractor to install the appropriate devices as required to meet your local codes NOTE ANY METAL PLUMBING PROVIDED DURING INSTALLATION MUST BE BONDED WITH A 8 AWG W...

Page 12: ...and service If necessary contact the manufacturer or supplier to arrange for any repair or replacement parts that may be needed Upon completion of water testing the system install the enclosure skirt...

Page 13: ...er drop or insert any object into any opening 6 For the protection of you and your customer from being exposed to an electrical fault this unit is equipped with a GFCI Ground Fault Circuit Interrupter...

Page 14: ...ycle 20 min on 20 min off Connect only to a circuit that is protected by a ground fault Circuit Interrupter GFCI MODEL SERIAL NUMBER MFG DATE VOLTS AMPERAGE FREQUENCY POWER IP NUMBERS PHASES The Biarr...

Page 15: ...CITIES WARRANTIES Dimensions Upright 56 144 cm L x 42 108 cm W x 57 146 cm H Reclined Up to 78 200 cm L x 42 108 cm W x 37 95 cm H Individual Dimensions Chair 30 77 cm Upright 46 118 cm Reclined L x 4...

Page 16: ...alteration or repair or if the product was not installed in accordance with Techno Spa s printed installation and operation instructions 2 To obtain service under this warranty contact Techno Spa for...

Page 17: ...t illuminate condition Reset GFCI Check and or replace F1 fuse on Main Control Box Chair does not operate Check all above Make certain connector to chair is securely made Check to see that remote Cont...

Page 18: ...feed pipe to Biarritz Make sure Main Valve on Biarritz is fully open Make sure Cold Water feed from Main Supply is connected to Cold Water input on Biarritz Make sure Thermostatic valve is fully coun...