54
AGUADENS
COSMOGAS
8.5 - Condensate siphon
cleaning procedure
For correct cleaning of the collection siphon and the
conveying of the condensate produced by combustion,
operate as follows (refer to the figures 8.3, 8.4 and 8.5):
1.- with the appliance on, open a domestic hot water tap or
taps fully to force the burner to its maximum power and
the level of the liquid present inside the siphon tank “D”
lowers (see figure 8.4);
2.- access the internal components following paragraph 8.2;
3 - remove the burner fan unit following paragraph 8.3;
4 - cover the electric plant with a cloth to protect it from any
residues of water inside the siphon to be removed.
5.- slide the support “C” outwards from the holding support;
6.- slide the tank “D” downwards, paying attention to the
fact that it is full of condensate water and this could
escape;
7.- extract the siphon outwards (see figure 8.6) paying
attention to disconnect the collection pipes of the water
coming from the upper part of the appliance and from the
air vent valve.
8.- clean the decanting tank “D”;
9.- re-mount everything in reverse order, paying attention to
the gasket “E”, which is put back in the relevant seat and
that terminal “G” is introduced correctly in the seat “H”;
10.- restore the level of liquid inside the siphon following the
procedure in chapter 6.1.2.
Figure 8.4 - Removing condensate collection
siphon
Figure 8.5 - Condensate collection siphon
H
G
F
D
E
020002.01.030
8 - MAINTENANCE
Figure 8.3 - Removal of the condensate collection
siphon
B
C
A
020003.01.027
D
020003.01.029