17
GAS SUPPLY REQUIREMENTS
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does
not exceed the maximum pressure listed in this section.
Examples of a qualified person include:
•
licensed heating personnel
•
authorized gas company personnel
•
authorized service personnel
Failure to do so can result in death, explosion or fire.
IMPORTANT:
TYPE OF GAS
Natural Gas:
This range is design-certified by CSA International for use with natural gas or,
after proper conversion, for use with LP gas.
This range is factory-set for use with Natural gas. The model/serial rating
plate located on the right side oven door trim has information on the types of
gas that can be used. If the types of gas listed do not include the type of gas
available, check with the local gas supplier.
•
Observe all governing codes and ordinances.
•
This installation must conform with all local codes and ordinances. In the
absence of local codes, installation must conform with American National
Standard, National Fuel Gas Code ANSI Z223.1 - latest edition or, in
Canada, CAN/CGA B149 - latest edition.
•
Leak testing of the range must be conducted according to the
manufacturer's instructions. Do not use a flame to check for leaks.
WARNING